Summary of Contents for ALICE CANALIZZATA

Page 1: ...CHANNELED PELLET STOVE ALICE CANALIZZATA OPERATING AND MAINTENANCE HANDBOOK...

Page 2: ...y know and use the product at its best as well as ordinarily upkeep it Our authorized technical service remains at Your complete disposal for any necessity Best regards Karmek One S R L PLEASE NOTE Ka...

Page 3: ...rting b 3 Positioning b 4 Channeling b 5 Installing the flue gas outlet b 6 Installing the combustion air inlet pipe b 7 Connecting to the power supply C OPERATING INSTRUCTIONS c 1 Initial warnings c...

Page 4: ...be d 9 Sparking plug d 10 Thermocouple E ORDINARY CLEANING AND MAINTENANCE e 1 Cleaning and maintenance by the customer e 2 Periodic maintenance by the Assistance Center F ALARMS DISPLAYING f 1 Fumes...

Page 5: ...raught before and after the combustion work of the stove While seasonally using the stove in case of bad draught of unfavorable weather conditions temperature lesser than 0 C verify if the flue is per...

Page 6: ...children close to the stove on their own when it is on because each hot surface can provoke severe burns Do not perform interventions on the stove apart from those expected for a regular functioning...

Page 7: ...g YES Adjustable feet YES Dimensions 877x1082x346mm Weight 100Kg Fuel pellet 6mm Fumes joint 80mm Air inlet 35mm Minimum safety distance from inflammable materials 200mm a 3 Accessory equipment The st...

Page 8: ...8 1 Side fumes outlet 2 Top fumes outlet 3 Rear fumes outlet 4 Combustion air inlet 5 Switch and power socket 6 Channeled air outlet...

Page 9: ...of various wooden materials pellets are compliant to DIN 51731 regulations The following list summarizes the main characteristics of recommended pellets Diameter 6 6 5mm Maximum length 20 25mm Calori...

Page 10: ...rformed with an elevation trolley by inserting the pitchforks in the proper slots of the wooden packing In order to position the stove inside a room a good general rule is to lay the stove on the floo...

Page 11: ...e gas outlet 80 Using an easy to inspect T joint reach the outside of the building horizontally proceed vertically until you reach the roof with a cohibented flue equipped with an anti wind chimneysta...

Page 12: ...12...

Page 13: ...flue b 7 Connecting to the power supply Verify if the electrical system and the mains outlets present the capacity to support the maximum absorption of the stove which is reported on the plate Make su...

Page 14: ...14 ELECTRICAL SCHEME...

Page 15: ...automatic management of the temperature of the lighting and the switching off with the possibility of a multiple days programming The automatic loading and the consistent capacity of the tank allow t...

Page 16: ...ed The following table shows the menu structure Only user accessible items are shown Menu item 01 set fans is available only if the corresponding function is enabled see Technical parameters Level 1 L...

Page 17: ...g 2 on off 19 sunday prog 2 on off 20 start prog 3 time 21 stop prog 3 time 22 monday prog 3 on off 23 tuesday prog 3 on off 24 wednesday prog 3 on off 25 thursday pog 3 on off 26 friday prog 3 on off...

Page 18: ...f the two fans independently The following settings are available for each of the two fans Press the keys P1 fan 2 and P2 fan 3 to adjust settings Value Fan 2 Fan 3 A Equal to selected power Equal to...

Page 19: ...le chrono Switches on or off all chronothermostat functions program day Enables disables and sets daily chronothermostat functions It is possible to set two working periods by adjusting start and stop...

Page 20: ...r disabled If the value of an item is set to OFF the corresponding command is ignored NOTICE It is important to program the stove with care avoiding overlapping working periods Program 1 menu level se...

Page 21: ...ime OFF 03 03 21 STOP PROG 3 switching off time time OFF 03 03 22 MONDAY PROG 3 day of application on off 03 03 23 TUESDAY PROG 3 on off 03 03 24 WEDNESDAY PROG 3 on off 03 03 25 THURSDAY PROG 3 on of...

Page 22: ...t the same time choose the one that mostly fits your planning and disable the others C 7 select language Allows to select the language C 8 mode stand by Allows to enable STAND BY mode that switchs off...

Page 23: ...ng and with the stove cooled down allows to charge the grate with pellet for 90 Start charging with P1 key and stop with P4 C 11 state stove Displays the state of the stove reporting information about...

Page 24: ...Once lighting phase ends correctly the stove enters working mode that is the normal operating condition of the stove When fumes temperature is greater than Pr15 exchanger fans are turned on Fans N 2...

Page 25: ...mes that form in the combustion chamber This operation permits a perfect combustion and a better thermic efficiency d 3 Tangential fan The tangential fan intakes the room air and returns it hot by pus...

Page 26: ...n mode RIS d 8 Room probe The room probe is positioned on the back of the stove and it surveys the temperature of the room where the stove is located d 9 Sparking plug The sparking plug permits the pr...

Page 27: ...ipe of the stove Remove the furnace s internal covering accurately clean and remove the incrustations inside the crucible and its space Clean the fans and check the mechanism of the plays and of the f...

Page 28: ...NO FIRE Fire went off while in working mode ALARM NO FIRE Fumes motor failure ALARM DEP FAIL IF ANY ALARM OCCURS THE STOVES IMMEDIATELY ENTERS SWITCH OFF PHASE Alarm state is reached after the time s...

Page 29: ...rmi ensues when the smoke intake motor fails As in all the other alarms the stove immediately starts switching off G WASTE MATERIAL Do not drop electrical devices among domestic waste According to the...

Page 30: ...sive accumulation of pellets in the grate Clean the grate The stove does not light automatically The resistance does not reach its temperature Check the electric cables and fuses Request the assistanc...

Page 31: ...ean Too humid pellets Check the quality of the pellets Excessive quantity of pellets in the tank Contact the authorized assistance center Wind contrary to the outlet flow Check the anti wind terminal...

Page 32: ...elle foibe 17 31015 Conegliano TV phone 0438 1883101 fax 0438 1883103 e mail info karmek it GUARANTEE CONDITIONS AT THE END OF EACH SEASON IT IS OBLIGATORY TO HAVE THE AUTHORIZED ASSISTANCE CENTER PER...