c.9 Managing the automatic lighting (chronothermostat)
The automatic lighting function permits to weekly program the lighting and switching off of the
boiler. Through this function, it is possible to set two daily lightings; it is also possible to avoid extra
programming, by memorizing the set data.
Press the “set” key once to set the water temperature.
Press the “set” key twice to set the room temperature.
Clock set
UT1
Clock day
OFF; Day1, Day2…Day7
UT2
Clock hours
From 00 to 23
UT3
Clock minutes
From 00 to 59
Chrono set
UT5
Start program 1
From 00:00 to 23:50, 10’ step
UT6
Stop program 1
From 00:00 to 23:50, 10’ step
UT7
Daily lighting/switching off
Between on/off for 1 to 7 days
UT8
Start program 1
From 00:00 to 23:50, 10’ step
UT9
Stop program 1
From 00:00 to 23:50, 10’ step
UT10
Daily lighting/switching off
Between on/off for 1 to 7 days
UT01: You need this setting to set the current day of the week or to unset the program, according
to the scheme reported below.
Day1
Monday
Day 2
Tuesday
Day 3
Wednesday
Day 4
Thursday
Day 5
Friday
Day 6
Saturday
Day 7
Sunday
OFF
Unset chronothermostat
UT05/UT06: they indicate the starting and stopping time of the Program 1, if the UT01 setting is set
on the weekly mode (different from OFF)