30
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
The
boiler
is
precociously
jammed,
and
presents
an
irregular combustion.
Flue jammed or too long.
Too humid pellets.
Excessive quantity of pellets
in the tank.
Wind contrary to the outlet
flow.
Insufficient intake in the grate.
Recent change in the kind of
pellets used.
See the paragraph about the
installation of the boiler.
Check if the flue is clean.
Check the quality of the pellets.
Contact the authorized assistance
center.
Check the anti-wind terminal and/or
install it if necessary.
Check if the grate is correctly
positioned and if it is clean; check is
the air intake pipe is clean.
Contact the authorized assistance
center.
Contact the authorized assistance
center.
Smell of smoke in the
room –
The boiler
switches off.
Bad combustion.
Malfunctioning of the fumes
fan.
The installation of the flue
was incorrectly performed.
Contact the authorized assistance
center.