THANKS

We at Kasco Marine, Inc. would like to both thank and 

congratulate you on your purchase of the Submersible 

LED Light Kit.  This kit will illuminate your fountain 

for a beautiful display.  We thank you for choosing 

Kasco for your fountain and aeration needs and want 

you to be completely satisfied with your purchase.

Important Safety

Please read and follow these extremely important 

safety and handling instructions for your Kasco equip-

ment.  Following these instructions will help ensure 

your safety and the quality performance of your equip-

ment.

• 

Under NO circumstances should anyone enter 

the water with the electrical equipment plugged 

in and/or in operation.  All Kasco equipment is 

designed and built for use in water, and control 

panels are available with GFCI protection.  How-

ever, it is NEVER recommended to enter the water 

with the equipment in operation.

• 

Kasco’s Submersible Light Kits are intended for 

use with a Listed control panel having a GFCI 

protected receptacle, or field wiring terminals and 

disconnect switch, or a timer with a disconnect for 

use with a GFCI receptacle.  They are intended 

to be mounted on a floating fountain or aerator 

for use in a natural or man-made body of water to 

comply with NEC Article 682.

• 

Kasco’s Submersible Light Kits have not been 

evaluated for use in swimming pools, spas or sta-

tionary fountains.

• 

The power connection for the light kit is 120Vac 

and MUST be plugged into a GFCI protected 

receptacle or GFCI protected field terminal con

-

nections.

• 

Caution should be used when dealing with any 

electrical and/or moving equipment.

• 

NEVER run the unit out of water.  It could create a 

dangerous situation for the operator.

• 

Extreme caution should be used around water, es-

pecially cold water, as in Spring, Fall, and Winter, 

which poses a hazard itself.

• 

NEVER lift or drag the fountain or light kit by the 

power cords.  If you need to pull the unit to the 

side of the pond, use the anchoring ropes.

• 

Do not use waders in ponds/lakes that are deep, 

with drop-offs, drastic slopes, or soft bottom mate-

rial.

• 

Do not use a canoe or boat that tips easily during 

installation 

• 

To reduce the risk of electrical shock, be certain 

the light kit is connected to the GFCI protected 

lighting circuit of your control panel.  For more 

information regarding your control panel instruc-

tions, refer to your fountain owner’s manual or 

download control panel wiring diagrams from 

http://kascomarine.com/instructions.html. A con-

trol panel must be installed a minimum of 5 feet 

(3m in Canada) from the body of water unless 

separated from the body of water by a fence, wall, 

or other permanent barrier that will make the unit 

inaccessible to persons in the water.

General Instructions

INSPECT THE SHIPMENT

Immediately inspect this shipment for any visible 

damages.  Also cross reference the “Parts Included” 

section to check for part shortages.  Shortages should 

be reported immediately to your Kasco Marine distrib-

utor or representative and damages reported to your 

carrier and Kasco Marine.

Parts Included

LED3125

• 

A.  Light Kit cord with waterproof connectors (1)

•  B.  Sealed LED light fixtures with Stainless steel 

mounting brackets (3)

• 

C.  1/4” x 1 3/8” Stainless Steel Bolts (3)

• 

D.  1/4” Stainless Steel Flat Washer (3)

• 

E.  1/4” Stainless Steel Lock Washer (3)

• 

F.  1/4” Stainless Steel Nut (3)

• 

G.  Nylon Cable Ties (10)

•  H.  Protective flex sleeve 36inch (3)

• 

I.   Sealing cap (3)

• 

J.  4” spacer washers (3)

• 

K. 1/4” x 5” Stainless Steel Bolts (3)

• 

L.  Spare Oring (1)

• 

M. Rubber caps (3)

• 

N.  Colored lenses (20 - 4 of each color)

Note: Extra hardware may be included.  One extra 

spare oring is included. One extra lens of each color is 

included.

Summary of Contents for LED3125

Page 1: ...uded pg2 LED3125 Assembly Instructions pg3 Instructions For Mounting LED6125 pg5 Maintenance Recommendations pg6 Warranty Policy pg7 Troubleshooting Tips pg8 Customer Repair Form pg9 Registration Information pg12 Rev 02 26 13 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com ...

Page 2: ...d be used around water es pecially cold water as in Spring Fall and Winter which poses a hazard itself NEVER lift or drag the fountain or light kit by the power cords If you need to pull the unit to the side of the pond use the anchoring ropes Do not use waders in ponds lakes that are deep with drop offs drastic slopes or soft bottom mate rial Do not use a canoe or boat that tips easily during ins...

Page 3: ...h Fig 5 flat washer lock washer 1 4 nut LED6125 A Includes two 2 sets of LED3125 see parts included in LED3125 B Lower float brackets 6 C 3 8 washers 3 TOOLS SUPPLIES NEEDED A Two 7 16 Wrenches or one wrench a 7 16 socket with driver B Diagonal Pliers or Cutter for Nylon Zip Ties LED3125 Assembly Instructions For ease of assembly make sure the Aerating Fountain is completely assembled Place the as...

Page 4: ... 5 3VFX 7 3JF 4 Insert the 1 4 x 5 bolt into the light bracket and extension as shown in Figure 9 Place this assembly on the float bracket Fig 9 6 Adjust the angle of the light as desired and tighten the two brass thumb screws on the sides of the fixture until snug Do not over tighten It is best to have all three fixtures at the same angle 7 Repeat steps 1 through 4 for the remaining fixtures Asse...

Page 5: ...e until snug Do not over tighten It is best to have all three fixtures at the same angle 7 Repeat steps 1 through 4 for the remaining fixtures Assembled light fixtures are pictured in Figure 4 Note the orientation of the lights 8 Connect each fixture cord to the power cord s wa terproof connectors Make sure the orange oring is installed on the plug side of the waterproof connector If any are miss ...

Page 6: ... lens of the light fixtures is clean to ensure the brightest light possible FIXTURE REPLACEMENT The LED light fixtures are sealed and do not require any maintenance other than cleaning If a fixture fails to operate it can be removed and the sealing cap installed onto the waterproof connector of the power cord This will allow you to continue to operate your light kit with two fixtures while a repla...

Page 7: ... and service The Kasco Marine Inc obligation under this warranty is limited to replacing or repairing free of charge any defective part within one 1 year from the date of shipment Customer shall pay ship ping charges for returning the unit to Kasco THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED AND ANY OTHER OBLIGATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE INC AN...

Page 8: ...g the light kit in and see if it operates If the GFCI trips again then the light kit may be damaged If the GFCI does not reset with light kit unplugged then it may be defective or the photo eye is not activated to send power to the outlet C 85 or C 95 control panel with terminal connections and timer control for light kit For panels with a GFCB ground fault circuit breaker and timer controlled lig...

Page 9: ...ed for warranty repair Do not ship the control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number ___________________ City ____________________ Email Address ______________________ State _____________________ Zip Code ____________...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...________ Serial Ex 2101LEDA3001 ____________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884012 ...

Reviews: