background image

 

 

8400JF PARTS INCLUDED 

 
A.  8400JF Aerating Fountain (Unit with cord or unit with Disconnect) (1) 
A1. Cord in separate box (1) (depending on size of cord) 
B.   Float in separate box (1) (Diagram to Right) 
 

1.  3 Float Sections (1) 

 

2.  Top Float Bracket (3) 

 

3.  Bottom Float Bracket w/ 50’ rope (3) 

 

4.  9” x 3/8” Black Coated Bolt (6) 

 

5.  3/8” Lock Nut (6) 

 

6.  Unit Mounting Bracket (3) 

 

7.  1/4” x 3/4” Bolt (9) 

 

8.  1/4” Lock Washer (12) 

 

9.  Bottom Screen (1) 

 

10.  Top Screen (1) 

 

11.  Top Screen Clip (3) 

 

12.  1/4” Nut (6) 

 

13.  Bottom Screen Clip (3) 

 

14.  1/4-20 x 3/4” Brass Screw (3) 

C.  C-85 Control Panel in separate box (1) 
D.  Set of Five Interchangeable Nozzles (5) (Diagram to Right) 
 

1.  #6 x 1/2” Phillip Pan Head Self Tapping Screw (3) 

 

2.  3/8” x 4” bolt (1) 

 

3.  Linden Nozzle (1) 

 

4.  Redwood Nozzle Y Insert (comes installed in #7)(1) 

 

5.  Juniper Nozzle (1) 

 

6.  Willow Nozzle (1) 

 

7.  Redwood & Spruce Nozzle (1) 

 

NOTE:  Extra hardware may be included. 

 

TOOLS & SUPPLIES NEEDED 

 
A.  Anchors or stakes for installing unit (3) 
B.  Philips head screw driver for mounting C-85  
C.  240V Electrical Supply near pond on a post with room for 

mounting the C-85  

D.  Three 12” galvanized pipe for weighting ropes (optional) 
G.  #10 x 1” long or longer screw(s) for mounting the C-85 (4) 
H.  7/16” Socket & Wrench (1) 
I.  7/16” Wrench (1) 
J.  9/16” Socket & Wrench (1) 
K.  9/16” Wrench or adjustable crescent wrench (1) 
L.  Flat head screw driver (1) 
 

UNIT SPECS. 

Model   

Voltage 

Operating  

  Lock Rotor     

Control Box   

 

Fountain  

    Amps 

  

 

Amps 

  Connection 

  Connection 

8400JF  

208-240 

10.5 @ 240V    40 @ 240V   

C-85 Hardwired 

 

Plug or Hard- 

 

 

 

 

 

 

 

 

 

at shore 

 

 

Wire in C-85 

 

 8400JF Power Cords 

Length Voltage Gauge 

Cord Shipped 

Seperately 

50 240 14 

No 

100 

240 

12 

Yes 

150 240  12 

Yes 

200 

240 

12 

Yes 

250 

240 

12 

Yes 

Summary of Contents for 8400JF

Page 1: ...sembly Installation Instructions Nozzles Pattern Sizes C 85 Control Panel Instructions For 8400JF 3 1JF C 95 Control Panel Instructions For 5 1JF Maintenance Recommendations Warranty Warranty Claim Re...

Page 2: ...er with the equipment in opera tion Caution should be used when dealing with any electrical and or moving equipment NEVER run the unit out of water It will damage the seals and create a dangerous situ...

Page 3: ...Kasco Marine backs each 8400JF 3 1JF and 5 1JF Aerating Foun tain with a 2 Year Warranty This warranty covers any and all manufacturers defects within 2 years from the date of purchase See Warranty Wa...

Page 4: ...zle Y Insert comes installed in 7 1 5 Juniper Nozzle 1 6 Willow Nozzle 1 7 Redwood Spruce Nozzle 1 NOTE Extra hardware may be included TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 3 B...

Page 5: ...3 Linden Nozzle 1 4 Redwood Nozzle Y Insert comes installed in 7 1 5 Juniper Nozzle 1 6 Willow Nozzle 1 7 Redwood Spruce Nozzle 1 NOTE Extra hardware may be included TOOLS SUPPLIES NEEDED A Anchors or...

Page 6: ...now be extending through the assem bly Loosely install the six 3 8 Lock Nuts Part B5 on the ends of the bolts do not tighten yet Connect the Top and Bottom Float Brackets using three 1 4 x 3 4 Bolts...

Page 7: ...on the nozzle and tighten the screws into the cone assembly Once you feel resistance two more turns will be sufficient To install the Spruce nozzle follow the same steps but do not install the Y Inse...

Page 8: ...e wire stripped portion of the WHITE wire into 2 and the bare wire stripped por tion of the BLACK wire into 4 Tighten both lugs securely Replace metal barrier plate in panel Test the GFCB with the tes...

Page 9: ...Juniper Nozzle 1 6 Willow Nozzle 1 7 Redwood Spruce Nozzle 1 8 Sequoia Nozzle 9 3 8 x 2 5 Bolt 1 NOTE Extra hardware may be included TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 3 B P...

Page 10: ...rough the assem bly Loosely install the six 3 8 Lock Nuts Part B5 on the ends of the bolts do not tighten yet Connect the Top and Bottom Float Brackets using three 1 4 x 3 4 Bolts Part B7 with three 1...

Page 11: ...d in the 3 holes on the nozzle and tighten the screws into the cone assembly Once you feel resistance two more turns will be sufficient To install the Spruce nozzle follow the same steps but do not in...

Page 12: ...FCB with the test button now and every 30 days If lights are installed they can now be in stalled per Instructions included with the lights Once completed power can be restored to the panel ENJOY YOUR...

Page 13: ...ed L inside one of the fins uses the 3 8 x 4 bolt LINDEN Model HP Height Width 8400JF 2 18 30 3 1JF 3 19 35 5 1JF 5 20 35 The Willow nozzle marked W on the inside of the cone uses the 3 8 x 4 bolt WIL...

Page 14: ...L to proper time of day See step 2 above ON TRIPPER TIME POINTER TIME DIAL OFF TRIPPER MANUAL LEVER Wiring information Copper Conductors Wire Terminal Size Tightening Torque AWG Lb In 14 20 12 20 10 2...

Page 15: ...ON TRIPPER TIME POINTER TIME DIAL OFF TRIPPER MANUAL LEVER Wiring information Copper Conductors Wire Terminal Size Tightening Torque AWG Lb In 14 20 12 20 10 20 8 25 6 35 4 45 3 50 2 50 IMPORTANT Thi...

Page 16: ...ter is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and c...

Page 17: ...d under warranty The Fountain is damaged by unauthorized tampering The Sacrificial Zinc Anode around the propeller shaft shows significant deterioration The Anode must be inspected periodically and re...

Page 18: ...nse Kasco Marine will re turn units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially...

Page 19: ...W FILLISTER HEAD 3 7 990275 O RING CORD 1 8 890100 CAN 8400 SERIES 1 9 990280 SEALING PLUG 1 10 990281 O RING 1 11 820425 GREASE CAP FOR 8400 1 12 840400 LIP SEAL 5 8 2 13 475625 SCREW 10 24 X 2 5 LON...

Page 20: ...LLISTER HEAD 3 6 990275 O RING CORD 1 7 990280 SEALING PLUG 1 8 990281 O RING 1 9 820425 GREASE CAP FOR 8400 1 10 840400 LIP SEAL 5 8 2 11 475625 SCREW 10 24 X 2 5 LONG 3 12 475626 FLAT WASHER 10 3 13...

Page 21: ...HEAD 3 6 990275 O RING CORD 1 7 990280 SEALING PLUG 1 8 990281 O RING 1 9 820425 GREASE CAP FOR 8400 1 10 840400 LIP SEAL 5 8 2 11 475625 SCREW 10 24 X 2 5 LONG 3 12 475626 FLAT WASHER 10 3 13 475642...

Page 22: ...in has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged imm...

Page 23: ...for by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for...

Page 24: ...egister your fountain online at www kascomarine com general_info_warranty_registration htm Also fill in the information below and keep for your records Model Ex 3 1JF _______________________________ S...

Reviews: