MAINTENANCE RECOMMENDATIONS

DO NOT ENTER THE WATER with the electrical equipment plugged in and/ or in operation. 

Please keep the original box for maintenance shipping. 

Proper Installation 

Ensure a power source with ground fault protection. Test the protection 

device upon installation, after each re-installation, and monthly thereafter to ensure proper 

operation. In the event of repeated trips, disconnected the equipment and it from the water. 

Inspect the power cord for damage and consult a qualified electrician.

Observation

 Observe operating equipment regularly for any variation in performance. If you 

observe a change in performance, disconnect the equipment from its power source and inspect 

for any material that may have wrapped around the shaft of the motor, especially plastic bags and 

fishing line. Remove these as soon as possible.

Winter Storage 

In regions where there is significant freezing , remove the circulator from the 

water in wintertime. Store the unit out of the sun and above freezing temperatures. During the 

offseason, store the unit on its side to help prevent the seals from drying out.

Cleaning 

Remove circulators from the water at least once per year to clean the exterior of the 

system, especially the stainless steel motor housing (can) to avoid build-up of algae, calcium, or 

other materials. This buildup can lead to overheating. In warmer regions, Kasco recommends 

removing the motor and cleaning it at least two to three times per year, depending on conditions. 

Seal & Oil Replacement

 

Replace the seals and change the oil every three years. In warmer 

climates where the circulator runs most or all of the year, replace seals more regularly than you 

would need to in colder climates. 

Sacrificial Anode

 

A sacrificial anode on the shaft of the circulator protects equipment from 

corrosion and electrolysis. Replace the anode if it is reduced to half the original size or if it is white 

in color. Check the anode at least every two to three months. 

Repair services should be performed by Kasco Marine or a Kasco authorized repair center. 

Any unauthorized alterations or to Kasco units will void the warranty. Please contact Kasco for 

information on your nearest Authorized Repair Center. 

Summary of Contents for AquatiClear 2400EC

Page 1: ...ott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 CIRCULATOR Operation Maintenance Manual Document 884149 Version 2021 1 0 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 AquatiClear 50 Hz ...

Page 2: ...cal and or moving equipment NEVER run the unit out of water NEVER lift or drag the equipment by the power cord Follow all boating safety rules and regulations during installation Single phase units are supplied with an internal grounding conductor and a grounding type attachment plug To reduce the risk of electrical shock be certain that the unit is plugged into a protected circuit Control panels ...

Page 3: ...arine backs each AquatiClear unit with a 2 Year Warranty This warranty covers any and all manufacturer s defects within the warranty period from the date of purchase Use and Operation Kasco Circulators are designed and engineered for continuous duty Upon installation your Kasco AquatiClear is ready for immediate use Make sure to keep the motor housing clean from hard water deposits and or algae Mo...

Page 4: ... 243410 B 1 2 washer 1 475642 C Propeller 2400EC 1 340135 C Propeller 3400EC 1 440435 D AquatiClear prop guard 1 993210 E 1 4 20 x 1 1 2 screw 3 475695 F Retaining clip 3 140312 G 1 4 20 nut 3 840538 H Sealed motor unit 1 N A I Prop stop 1 440630 J Sacrificial anode 1 243474 F A B D C E G H I J ...

Page 5: ...The upper mount can be secured horizontally as shown above or vertically right allowing installation options for a variety of shoreline structures Easily lower angle and position units for proper water movement Mount to a dock piling wall or other in water property Packages include upper and lower mount assemblies pipe supplied by customer Float Mount Kasco s Horizontal Float suspends the unit in ...

Page 6: ...n and above freezing temperatures During the offseason store the unit on its side to help prevent the seals from drying out Cleaning Remove circulators from the water at least once per year to clean the exterior of the system especially the stainless steel motor housing can to avoid build up of algae calcium or other materials This buildup can lead to overheating In warmer regions Kasco recommends...

Page 7: ...hese symptoms the unit should be unplugged immediately because the thermal overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the cause of the problem The problem could be low water levels build up on the unit preventing heat dissipation something inhibiting the free rotation of the shaft etc If somethi...

Page 8: ...AQUATICLEAR CIRCULATOR MANUAL 8 SACRIFICIAL ANODE REPLACEMENT A B C 1 2 E F G 3 6 4 5 x 3 Tighten this nut first and proceed counterclockwise 7 ...

Page 9: ...CI control box The equipment is damaged by unauthorized tampering The sacrificial anode around the propeller shaft shows significant deterioration The anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Warranty period is established by the original receipt For efficient service please register the unit online www kascomarine com Once warranty coverage has been ...

Page 10: ... Customer pre approves repair of the unit if costs are below a stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the customer specifies otherwise If the customer would like the product returned Kasco will return the unit to the condition in which we receive...

Page 11: ...hemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the cust...