UNIT SPECS.
Model
Voltage
Operating
Lock Rotor
Amps
Amps
F2400D
110-120
5.0 @ 120V 12 @ 120V
F3400D
110-120
6.7 @ 120V 18 @ 120V
F3400HD
208-240
3.4 @ 240V 9 @ 240V
4400D
110-120
11.3 @ 120V 40 @ 120V
4400HD
208-240
5.7 @ 240V 20 @ 240V
and allow the unit to hang at a slight angle. After installation and the unit is turned on, your Kasco De-Icer
will swing up to an angle (the angle is dependent on how many cage wires you move the line) and the De-Icer
will hold that angle during operation. This allows you to aim the flow of warmer water in the desired location.
If the Universal Dock Mount or Horizontal Float were purchased, see their Assembly and Installation Instruc-
tions later in this manual.
STEP FIVE
Once your De-Icer is properly installed and secured, you can now plug the unit into a properly grounded and
GFI protected circuit. If a C-10 Thermostat or C-20 Timer/Thermostat Controller was purchased, they can be
plugged into the outlet receptacle and the De-Icer plugged into the controller. See Controller Instructions later
in this manual.
STEP SIX (OPTIONAL)
On installations where open water area is required or de-
sired to be limited/controlled, a curtain technique can be
used to block the flow of water and restrict the open wa-
ter area. By draping a canvas tarp as a curtain in the wa-
ter, you can successfully disrupt the flow of water from
the De-Icer. The canvas can be tied above the water
level and weighted at the bottom (easiest if you fold the
tarp in half and lay a chain in the fold as the weight).
The curtain needs to hang into the water a few feet. This
curtain will allow you to protect only the area you need.
As always, we recommend the ice-free area is well
marked.
9
Kasco De-Icer Sizing Chart
Average Low Air Temperature (
O
F)
34
O
-20
O
Orientation 19
O
- 0
O
Orientation
Minus 1
O
to Minus
20
O
Orientation Great Lakes Orientation
HP Size
Angled
Vertical Angled Vertical Angled Vertical Angled Vertical
1/2 HP
30' x 100'
65'
25' x 60'
50'
25' x 50'
45'
20' x 40'
35'
3/4 HP
35' x 120'
85'
30' x 80'
70'
30' x 75'
65'
25' x 50'
45'
1 HP
40' x 150'
95'
35' x 90'
80'
35' x 85'
75'
30' x 60'
55'
Assumption:
Unobstruted water
200 acre plus body of water with 20 feet plus maximum water depth or greater
Water depth in de-icing area 4 feet plus
* Size may vary greatly based on a number of local conditions