background image

 
 

 

USER’S INSTRUCTIONS

 

IST-USO-0905100 

Rev. 1 – 11/01/2017 

IDP 109 

Page 1 of 2

  

 

 

PROF88 – KOMPAT88 

 

POWERED AIR PURIFYING RESPIRATORS 

 

Respirator composition chart: 
 

Respirator 

Part # 

Code 

Helmet 

Filter

 

Battery Charger 

Airflow 

indicator 

 

NIOSH APPROVAL 

0313072 

PROF88 

0302032

 

2 X ZP3 

0601023 

NC-9 

0105082 

0806010 

TC-21C-633 

0313143 

KOMPAT88 

0302029

 

2 X ZP3 

0601023 

NC-9 

0105082 

0806010 

TC-21C-633 

 

1. DESCRIPTION

 

1.1 HELMET: It is composed of: a fiberglass shell covered with 3 coats of paint, 

the last one of which, the most external one, is polyurethane; a polycarbonate 
visor;  a  polyamide  collar  which  closes  efficiently  and  comfortably  round  the 
operator's neck; a head-band adjustable from 53 to 63 cm (6-5/8 to 7-7/8 hat 
size). 

 

1.2 BLOWER UNITS (built into the helmet): They are located in a plastic housing 

and are composed of a fan actuated by an electric micro motor. 

 
1.3  BATTERY  ASSEMBLY  (built  into  the  helmet):  It  is  composed  of:  Nickel 

Cadmium batteries connected in series. 

 
1.4  BATTERY  CHARGER:  It  is  composed  of:  a  stabilized  battery  charger  and 

includes electric cord and plug. 
 

1.5  ZP3  FILTERS:  made  of  finely  pleated  technical  paper  packed  into  plastic 

housing . 

 
1.6 AIRFLOW INDICATOR: It is composed of a transparent tube with indicator ball 

inside.  The  indicator  is  needed  to  check  the  airflow  performance  of  the 
respirator it is supplied with, before each use. 

 

2. TECHNICAL CHARACTERISTICS

 

2.1 HELMET: 
-  Shell :  Fiberglass   -  Face  shield :  Polycarbonate  –  Head  suspension: 
Polyethylene – Face shield gasket: polyethylene foam. 
- Noise level < 80Db. 

 

2.2 BLOWER UNITS  

Type of unit 

Type of 
 filter 

N. of 
filters 

Voltage 
 
 
 
- Volts 

Airflow at 
20°C  60% 
R.H. .-Battery 
fully charged 
- Lpm 

Expected   
micro motor  
life 
 
- Hours 

PROF88 
KOMPAT88 

ZP3 

 

 

10,8 

 

>170 

 

800 

 

 

2.3 BATTERY ASSEMBLY 

Type of 
blower 
unit 

Type of 
battery 

No. of 
batteries 
connected 
in series 

Voltage 
 
 
- Volts 

Terminal 
voltage 
under load 
- Volts 

Running 
time at 
20°C  
- Hours 

Approx.
battery 
life 

PROF88 

KOMPAT8

NI-CD 

2,2Ah 

10,8 

>4 

2 years 

or 

300 

cycles 

 
- Cycle service life: 
 

300 for discharges of 100% 

 

1500 for discharges of 50% 

 

2500 for discharges of 30% 

 
2.4 BATTERY CHARGER 

Type of unit 

Charger Model 

INPUT  

OUTPUT 

 

Charging 

time 

Hours 

PROF88 

KOMPAT88 

NC-9 

110V  60Hz 

12,8V 

  400mA

 

 6 

 

2.5 ZP3 FILTER (0601023): 

HE – High Efficiency Particulate Air filter for powered, air-purifying respirators. 

(See also label and Users’ Instructions packed with filter)

When the HEPA filter is exhausted, an increase in drop pressure is registered on 
the filter. This is indicated by a progressive diminishing of the airflow inside the 
respirator.

 

 

 
 
3. OPERATION 

3.1  The  blower  units,  powered  by  the  built-in  rechargeable  batteries,  take  in  air 

through  the  filters  and  send  it  to  the  inside  of  the  helmet.  The  helmet  goes 
into positive over pressure and the wearer breathes filtered air. Expired air is 
expelled through the diaphragm valves. 

 

4 USE 

4.1  For  the  protection  of  the  eyes  and  respiratory  system  of  the  wearer  while 

working in non I.D.H.L. environments containing dusts, fumes and  mists.  

 

4.2 LIMITATIONS  

 

Do not use in atmospheres immediately dangerous to life or health. 

 

Do  not  wear  for  protection  against  vapors  and  gas,  carbon  monoxide  (CO), 

natural gas and fumigants. 

 

Do not use in closed environments (tanks, silos etc.). 

 

Do not use for fire fighting. 

 

Do not use in atmospheres containing less than 19.5% oxygen. 

 

Do not use in explosive atmospheres. 

 

Do not exceed max. use concentrations established by regulatory standards.  

 

5. OPERATING INSTRUCTIONS 

5.1a BATTERY RECHARGING USING NC-9 BATTERY CHARGER. 

 

Plug the battery charger into mains. 

 

Connect battery charger to the discharged battery. 

 

Battery recharging is automatic. (Red led).

 

Led turns GREEN when battery is 

about 90% charged. 

 

The battery charger may remain plugged into the fully charged battery with no 
overcharge risk provided it is energized. 
(See also instructions packed with battery charger) 

 

5.2 HELMET SET-UP 

 

Remove  protective  film  from  visor.  The  film  was  applied  to  preserve  the 

transparency of the polycarbonate until the moment of use. 

 

Fit the helmet on head steadily. 

 

Adjust head band fit. 

 
5.3 DONNING INSTRUCTIONS: 
DON PAPR IN AN UNCONTAMINATED ENVIRONMENT. 

 

Don helmet and tighten collar drawstring around neck by pressing the button 

and sliding it up the drawstring. The drawstring should be pulled as close as 
possible  around  the  neck  to  assure  maximum  closure  but  it  should  at  all 
times feel comfortable and not restrict breathing in any way. 

 

for PROF88 respirator

: Close lift-up visor.  

 

5.4 AIRFLOW INDICATOR – Airflow checking test: 

 

 Make sure the Ni-Cad battery is fully charged. 

 

 Check that the filters are fitted into the helmet properly. 

 

 Open collar and keep it open throughout the test. 

 

 Switch the helmet ON. 

 

 Fit  the  airflow  indicator  over  the  right  hand  filter  and  position  so  that  the 

indicator is upright. 

 

 Check position of indicator ball:  

  If  it  rises  above  the  170  LPM  indication  line,  the  equipment  is  working 

properly. 

  If  it  remains  below  the  170  LPM  indication  line,  replace  the  filters  and 

repeat the test.  

  Should  the  ball  continue  to  stay  below  the  170  LPM  line,  recharge  the 

battery and repeat the test. 

  If  the  ball  still  remains below the 170 LPM line, replace the battery and 

repeat the complete test. 

  Fit the airflow indicator over the left filter and carry out the complete test as 

above. 

  Remove the airflow indicator. 

The PAPR may be used only if both tests (both left and right sides) give positive 
results.  Do  not  use  the  PAPR  with  airflow  indicators  fitted  over  the  filters.  The 

Reviews: