background image

10

800 Deere Rd.
Prescott, WI 54021
Phone: 715-262-4488  -  Fax: 715-262-4487
www.KascoMarine.com     Sales@KascoMarine.com

Customer Repair Form

* Important Reminders *
• 

All repairs sent in MUST be accompanied by a copy of this completed sheet!

•  Address your Repair to Kasco Marine, Attn: Repairs (or to your Authorized Repair Center.
•  Shipping to Kasco or an Authorized Repair Center is paid for by the customer.
• 

You must include the power cord with each unit sent in for repair to be considered for warranty repair!

•  Do not ship the control box with the unit for repair, unless otherwise instructed.

Today’s Date:___________________

Customer Information

Name: 

_________________ 

    Phone 

Number: 

_____________________

Address: __________________________ 

 

 

Alternate Number: ___________________

City: 

____________________    Email 

Address: 

______________________

State: _____________________

Zip Code: ______________________

Unit Information:

Model # (Ex. LED3S19): ____________________

Serial # (Ex. 2101LEDS3025)___________________

Date Purchased: ________________________

Purchased From: _________________________

Earliest Date of Problem: _______________________

Description of Problem:

Comments:

Summary of Contents for LED3S19-050

Page 1: ...ructions pg3 Instructions For Mounting LED6S19 pg5 Maintenance Recommendations pg5 Warranty Policy pg6 Troubleshooting Tips pg8 Replacement Parts pg9 Customer Repair Form pg10 Registration Information pg12 Rev 02 01 16 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com Submersible luminaire E478088 LISTED ...

Page 2: ...dangerous situation for the operator Extreme caution should be used around water es pecially cold water as in Spring Fall and Winter which poses a hazard itself NEVER lift or drag the fountain or light kit by the power cords If you need to pull the unit to the side of the pond use the anchoring ropes Do not use waders in ponds lakes that are deep with drop offs drastic slopes or soft bottom mate r...

Page 3: ... mounting brackets Fig 4 Stainless Steel Flat Washer 6 Stainless Steel Nut 6 x Stainless Steel Bolt 12 x 1 Stainless Steel Bolt 6 Nylon Cable Ties 12 Lower Float Brackets 6 3 8 Stainless Steel Flat Washers 3 TOOLS SUPPLIES NEEDED Two 7 16 wrenches or one wrench a 7 16 socket with driver Two 9 16 wrenches or one wrench a 9 16 socket with driver Wire Cutter for trimming cable ties LED3S19 Assembly I...

Page 4: ...ets Fig 9 6 Using the cable ties tie each ixture cord to bottom leg of mounting brackets using the holes provided The will act as a strain relief and will keep the cord from being damaged by the fountain and balance the unit properly Next cable tie the main power cord to the loat as shown in Fig 5 Fig 5 7 Upon installation of the assembled unit connect your LED light kit to your ield installed GFC...

Page 5: ...to electrical leaks in the equipment If you have repeat consistent trips of the ground fault device the equipment should be disconnected and removed from the water The power cord should be inspected for dam age and you should contact your distributor or call Kasco 6 Using the cable ties tie each ixture cord to bottom leg of mounting brackets using the holes provided The will act as a strain relief...

Page 6: ...possible for any reduction or variation in performance If a change in performance is ob served the equipment should be disconnected from power and inspected WINTER STORAGE In regions where there is signiicant freezing in the wintertime the fountain and light kit should be removed from the water to protect them from the expan sion pressure of the ice In many areas fountains will keep some amount of...

Page 7: ... restored as closely as possible to the condition in which it was received and shipped at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned to the customer and billed C O D unless otherwise directed Kasco Marine also accepts Visa and MasterCard credit card payments Kasco Marine will call for credit card information upon completion of the est...

Page 8: ...g the light kit in and see if it operates If the GFCI trips again then the light kit may be damaged If the GFCI does not reset with light kit unplugged then it may be defective or the photo eye is not activated to send power to the outlet C 85 or C 95 control panel with terminal connections and timer control for light kit For panels with a GFCB ground fault circuit breaker and timer controlled lig...

Page 9: ...W 1 4 20x1 2 2 2 840537 LOCK WASHER 1 4 2 3 346065 BRACKET S S LED MOUNTING 1 3 MODEL LEDxS19 xxx 19 WATT LED LIGHT FIXTURE REPLACEMENT PARTS 1 2 DO NOT ATTEMPT TO OPEN CONTACT KASCO MARINE FOR INSTRUCTIONS REGARDING SERVICE OR REPAIR Replacement Parts ...

Page 10: ...ed for warranty repair Do not ship the control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number ___________________ City ____________________ Email Address ______________________ State _____________________ Zip Code ____________...

Page 11: ...11 ...

Page 12: ...________ Serial Ex 2101LEDS3001 ____________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884050 ...