110/150
400 4F_11319.4.enu
The use of proprietary starting agents (such as Startpilot, for
example) is prohibited on account of the risk of explosion.
WARNING!
Risk of inhaling poisonous fumes!
Do not leave the engine running unattended or run-
ning in an enclosed space.
Start procedure
Ignition ON
Depending on the ambient temperature, the intake-air pre-
heating light goes out after approx. 2 seconds (no preheat-
ing) or within 30 seconds (maximum preheating time).
When the intake-air preheating light goes out:
Start the engine.
Do not depress the accelerator
- Operate the starter until the engine is turning at 700 rpm
- Maximum duration of start attempt 30 seconds
Engine refuses to start?
Immediately repeat the start attempt (do not repeat the
preheating procedure). It may take up to 30 seconds to
start.
If it is necessary to repeat the reheating
procedure:
Ignition OFF
Wait 5 - 10 seconds
Ignition ON
Starting the diesel engine