26
1. Before you install
Inspect both product and the contents of the package as soon as you receive them. Report
any transport damages to the deliverer.
1.1. Package contents and its inspection
The stove package contains:
•
Stove
•
Within the fire compartment
•
Installation instructions
•
Grate
•
Connection pipe
•
Door handle, mounting screw and nuts
•
Water tank, cap, casket and nut.
•
Water tank tap, casket and nut
•
Two steel caps (one sweeping caps in the space intended for stones and the back wall
flue hole has been bolted into place using a drilling screw drilled through the cover).
•
Ash pan
1.2. Important matters and regulations
In order to avoid damages during transport, the heater must be transported in an upright
position.
All sticker labels and packaging material must be removed before the heater is used. Type
plate must not be removed.
In addition to these instructions, all local regulations must be followed, including those
referring to local and European standards. They must be complied with when installing
the heater.
You must also find out about possible necessary building planning permissions and the floor
load capacity before installing the heater.
Before installing the chimney, you must also check the chimney's temperature class. T600
Check the following issues and how they affect where the heater should be installed:
•
Safety distance to flammable and non-flammable structures (sections 2.3 and 2.4)
•
Location of chimney connection (the height of the possible old chimney connection from
the floor and installation route of the chimney
•
Floor material (flammable, non-flammable, tiled, waterproof).
If heater is connected to a divided chimney (another stove has already been connected to the
chimney), each connection must have its own damper. Chimney is sized according to
larger stove.
Before beginning heating, also make sure that the smoke flue draft is sufficient and that the
heater is not damaged.
•
Draft in the chimney is -12Pa on nominal output.
•
Draft can be roughly checked for example by burning a bit of newsprint in the heater.
•
Before lighting, switch off equipment causing negative pressure, such as hood or
machine-operated ventilation. If the ventilation system has been equipped with a
fireplace switch, use it according to the system instructions.