background image

3)

Hold the filter upright and begin pumping the handle in a slow, steady manner. Make sure

the input hose is not kinked. 

4)

After filling water container with filtered water, remove bottle clip from container and input

hose from water source. Continue pumping to remove remaining water from pump body.

5)

Store the unit in the carry bag. To prevent the possibility of cross contamination remove the

output hose with the clip and store separately in the re-sealable bag inside the carry bag. 

*Note: Before each use, pump and discard a small amount (0.2 litres) of water to remove stale taste.

Field Performance Tips

The Katadyn Pocket is designed to remove bacteria and protozoan cysts such

as Legionella, Giardia and Cryptosporidium. 

To extend ceramic life, always use the best

water source available. Keep the input prefilter clean and off the bottom. In heavy sediment con-

ditions, wrap a coffee filter or bandanna around the input prefilter. Where possible, place untreat-

ed water in container and wait for sediment to settle out until water appears clear - then filter from

water above the sediment.

Maintain your Katadyn water system to keep it operating smoothly.

1)

If handle is hard to push: 

Clogged filter pores. 

If the filter pores of the ceramic are clogged, the ceramic needs

to be cleaned. Never use force when pumping. Unscrew the pump base counter- clockwise

from the lower end of the filter housing and remove the plastic sleeve by pulling it down-

wards. Clean the ceramic element by brushing it with the supplied cleaning pad until the

light, originally color appears again. Be careful not to have unfiltered water touching the

filter  output.  Push  the  plastic  sleeve  over  the  ceramic  element.  Apply  a  drop  of  silicone

lubricant on the thread of the pump base. Tighten the pump base clockwise. 

2)

Lubricate pump handle o-ring. 

Silicone Silicone lubricant is provided with your new

unit. Unscrew the handle collar on the upper part of the filter element counter clockwise and

remove the pump handle. (Figure 1-1) Clean excess build-up from black rubber o-ring on

bottom  of  handle.  Place  a  small  amount  of  silicone  lubricant  on  the  thread  of  the  filter

element. Re-assemble.

3)

If unit pumps easily, but no water flow:

Make sure prefilter is submerged.

Make sure that input hose is not blocked or pinched.

Hold the filter vertically until water flows.  

4)

Prefilter:

Rinse the prefilter in water to remove any particles that may be caught in the

strainer. 

5)

Storage:

Your Katadyn water system comes with a carry bag for storage. To prevent the

possibility  of  cross  contamination  remove  the  output  hose  with  the  bottle  clip  and  store

separately in the re-sealable bag inside the carry bag. 

8013888-3 Pocket Manual Content EU 11-sprachig_Manual EU  19.09.2012  08:32  Seite 4

Reviews: