Functional Specification

The electric heating prevents snow and ice formation on the antenna r

eflector surface which lead to interruptions in the 

satellite reception.

The heating for the antenna consists of a special heating mat with an integrated heat insulation and PTFE isolated 
heating elements.

After installation, the heating mat fits on the reflector in an optimum way and guarantees a good heat distribution. The 
heating mat has an integrated temperature switch that turns off the heating at 80 °C so that the system can be directly 
operated at 230 V/50 Hz. To ensure that operation is as economical as possible, it is recommended to use a control 
device (ESO 005).

Installation and Safety Instructions

DANGER

Danger to life from electric shock

!

 

Disconnect all devices and units from the power supply during installation.

 

In order to comply with the regulations for outdoor installation according to DIN VDE 0100 Part 610, it is 
recommended to have a residual current circuit breaker with a residual current of 0.03 A installed.

 

Make sure that the system is installed and connected only by qualified specialist personnel.

 

Make sure that modifications to electrical installations are only carried out by a specialist. Do not make any 
unauthorised changes yourself.

WARNING

Risk of severe injuries during installation due to falling from the roof, falling through the roof and falling 
parts!

 

Wear stable shoes with non-slip soles.

 

Use a working platform.

 

Make sure that the person carrying out the installation or repair has a secure position to stand and hold on whilst working.

 

Make sure that the person carrying out the installation or repair does not suffer from vertigo and can move 
around safely on the installation site.

 

Make sure that the vehicle roof is sufficiently strong and stable.

 

Make sure that there is nobody underneath the antenna during installation/dismantling.

 

Make sure that the roof and climbing aid are dry, clean and non-slip.

Installing the Reflector Heating

Required tools and equipment

 

Knife

 

Scissors

Installing the Heating Mat

1.  Clean and degrease the antenna back panel.

2.  Hold the heating mat on the antenna back panel to test the position.

3. 

NOTICE

Risk of material damage due to the incorrect attachment of the heating mat!

If the heating mat is not attached to the antenna in a correct way, it can tear while the adhesive film is being removed.

 

Make sure that the heating mat is aligned in the correct way. To do so, place the heating mat flush with 
the outer edge of the antenna and pay attention to the equal distance on the antenna bracket. After the 
heating mat has been secured, the correction is no longer possible!

4.  Remove the protective film from the adhesive area.

5.  Press the heating mat firmly to the antenna back panel. 

6.  To prevent moisture and insects from entering the heating mat, adhere the mesh-reinforced aluminium foil all along 

the edges of the mat.

Summary of Contents for 23710023

Page 1: ...____________________________________ As of 1 April 2019 KATHREIN SE s formerly KATHREIN WERKE KG Terrestrial Satellite Reception business unit will be transferred to KATHREIN Digital Systems GmbH limi...

Page 2: ...en Temperaturbereich von 40 bis 80 C transportieren und lagern Darauf achten dass kein Kondenswasser gebildet wird Bestimmungsgem er Gebrauch Die ESO 120 ist eine Reflektorheizung f r die Antenne CAS...

Page 3: ...arbeiten durch Absturz m glichen Durchbruch oder herabfallende Teile Feste und rutschsichere Schuhe tragen Arbeitsb hne verwenden Sicherstellen dass die montierende reparierende Person eine sichere St...

Page 4: ...l im Schaltschrank die Beheizung auf Durchgangs und Isolationswiderstand R pr fen Heizschale Durchgangswiderstand 5 Sollwert 70 1 77 5 Istwert Isolationswiderstand Sollwert 999 M Istwert ACHTUNG Diese...

Page 5: ...ung W ca 500 Leistung W ca 716 Isolationswiderstand M 20 Spannungsfestigkeit kV 2 5 Schutzart IP 65 Lebensdauer mind 10 Jahre Heizmattengewicht kg ca 0 5 Aufbau und Ausf hrung nach DIN VDE 0100 DIN EN...

Page 6: ...nd mechanical damage Transport and store the heating mat only in the permitted temperature range between 40 and 80 C Make sure there is no water condensation build up Intended Use The ESO 120 is a ref...

Page 7: ...of falling through the roof and falling parts Wear stable shoes with non slip soles Use a working platform Make sure that the person carrying out the installation or repair has a secure position to st...

Page 8: ...ntact resistance and insulation resistance R before connecting the cables in the control cabinet Heating tray Contact resistance 5 Target value 70 1 77 5 Actual value Insulation resistance Target valu...

Page 9: ...approx 716 Insulation resistance M 20 Dielectric strength kV 2 5 Protection class IP 65 Working life min 10 years Weight of the heating mat kg approx 0 5 Design and construction type according to DIN...