Accessories
General Information
Any previous data sheet issues have now become invalid.
Page 2 of 2
80010735
V01
936.4273/b
.1
Subject to alteration.
2)
3)
1934 | 76.1
1984 | 78.1
2024 | 79.7
1)
9 | 0.4
2) 72 | 2.8
3) 64 | 2.5
4) 99 | 3.9
5) 111 | 4.4
6) 70 | 2.8
Bottom view
Dimensions refer to radome
All dimensions in mm | inches
1)
303 | 11.9
4)
5)
6)
Correlation Table
Frequency range
Array
Connector
698 – 894 MHz
R1
1 – 2
Accessories
Type No.
Description
Remarks
mm | inches
Weight approx.
Units per antenna
kg
lb
738546
1 clamp
Mast diameter: 42 – 115 | 1.7 – 4.5
1.1
2.4
2 (included in the scope of supply)
86010149
1 iRCU
0.5
1.
1
1 (included in the scope of supply)
85010002
1 clamp
Mast diameter: 110 – 220 | 4.9 – 8.7
2.7
6.0
2 (order separately if required)
85010003
1 clamp
Mast diameter: 210 – 380 | 8.3 – 15.0
4.8
10.6
2 (order separately if required)
85010008
1 downtilt kit
Downtilt angle: 0° – 11°
4.3
9.5
1 (order separately if required)
Wall mounting: No additional mounting kit needed.
Mechanical specifi cations
Input
2 x 7-16 female
iRCU in: 1 x 8pin male
iRCU out: 1 x 8pin female
Connector position
Bottom
Wind load
N | lbf
Frontal:
750 | 169 (at 150 km/h) 1935 | 436 (at 150 mph)
Maximal:
825 | 185 (at 150 km/h) 2130 | 479 (at 150 mph)
Max. wind velocity
km/h
mph
241
150
Height/width/depth
mm
inches
1934 / 303 / 99
76.1 / 11.9 / 3.9
Category of mounting hardware
H (Heavy)
Weight
kg
lb
14 / 16 (clamps incl.)
30.9 / 35.3 (clamps incl.)
Packing size
mm
inches
2136 x 317 x 127
84.1 x 12.5 x 5
Scope of supply
Panel,
1
unit of iRCU and
2 units of clamps 42 – 115 mm | 1.7– 4.5 inches diameter
R1
Material:
Refl ector screen:
Weather-proof aluminum.
Radiator:
Tin-plated zinc.
iRCU housing:
Coated aluminum.
Fiberglass radome:
The grey fi berglass radomes of these antennas
are very stable and extraordinarily stiff. They are resistant to ultraviolet
radiation and can also be painted to match their surroundings.
All screws and nuts:
Stainless steel.
Grounding:
The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
Environmental tests:
iRCU additionally fulfi l the standards:
EN 60950-1 (Safety), EN 55022 (Emission) and EN 55024 (Immunity)
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com
Order Information
Model
Description
800
10
735V01
A
ntenna with mounting bracket
800
10
735V01K
A
ntenna with mounting bracket and
mechanical tilt bracket
Downloaded from