background image

936.4054/b

.1

     Subject to alteration.

86010149

   Page 1 of 2

Integrable Remote Control Unit (iRCU)

Type No.

86010149

Protocols

Compliant to AISG 1.1 and 3GPP/AISG 2.0

Logical interface ex factory 

1)

AISG 2.0/3GPP

Input voltage range

10 ... 30 V (pin 1, pin 6)

Power consumption

< 1 W (stand by); < 10 W (motor activated)

Connectors 

2)

2 x 8 pin connector according to IEC 60130-9; according to AISG

Daisy chain in: male; Daisy chain out: female

Hardware interfaces

RS 485A/B (pin 5, pin 3);

power supply (pin 1, pin 6); DC return (pin 7);

according to AISG / 3GPP

Adjustment time (full range)

40 sec (typically, depending on antenna type)

Adjustment cycles

> 50,000

Temperature range

–40 °C … +60 °C

Protection class

IP 24

Lightning protection

AISG interface (each pin);

2.5 kA (10/350µs); 8 kA (8/20µs)

Weight

480 g (1.1 lbs)

Packing size

245 x 93 x 102 mm, (9.6 x 3.6 x 4 inches)

Dimensions (H x W x D)

170 x 68.5 x 66 mm, (6.68 x 2.7 x 2.6 inches)

1)  

The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 and vice versa
with a vendor specifi c command.

Please note:

If the Primary of the RET system doesn’t support the standard of the ‘logical interface ex factory’, the 
iRCU must be switched to the appropriate standard of the Primary before installation. Please contact 
Kathrein for further information.

2)

 The tightning torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector
should be tightened by hand only!
Standards  

 EN 60950-1 (Safety)
EN 55022 (Emission)
EN 55024 (Immunity)
ETS 300019-1-4 (Environmental)

Certifi cation: 

CE, FCC15.107 class B

Scope of supply:  Integrable Remote Control Unit

Kathrein’s 86010149 integrable Remote Control Unit (iRCU) allow operators to control the 
 electrical tilt of compatible antennas without direct access to the antenna.

Compliant to AISG 1.1 and 3GPP/AISG 2.0

Field replaceable without dismantling the antenna

Daisy Chain feasibility

 Allow control of the antenna either locally through a laptop computer, on site desktop compu-
ter, the optional central control unit; remotely via an ethernet network or over the internet

Daisy chain in
(male)

Daisy chain out
(female)

Retaining Screw Torx 20

Bottom view of RCU

170 (6.68˝)

14.6 (0.57˝)

17.4 (0.68˝)

66 (2.6˝)

49.5 (1.45˝)

59.5 (2.34˝)

68.5 (2.7˝)

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082

Phone: 214.238.8800    Fax: 214.238.8801    Email: info@kathrein.com

All specifications are subject to change without notice.

The latest specifications are available at www.kathreinusa.com

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for 80010735V01

Page 1: ...ing instructions and warnings 1 The protocol of the logical interface can be switched from 3GPP AISG 2 0 to AISG 1 1 and vice versa with a vendor specific command Start up operation of the iRCU 86010149 is possible in a RET system supporting AISG 1 1 or supporting 3GPP AISG 2 0 after performing a layer 2 reset before address assignment The protocol can also be changed as follows AISG 1 1 to 3GPP E...

Page 2: ...Max wind velocity km h mph 241 150 Height width depth mm inches 1934 303 99 76 1 11 9 3 9 Category of mounting hardware H Heavy Weight kg lb 14 16 clamps incl 30 9 35 3 clamps incl Packing size mm inches 2136 x 317 x 127 84 1 x 12 5 x 5 Scope of supply Panel 1 unit of iRCU and 2 units of clamps 42 115 mm 1 7 4 5 inches diameter R1 Material Reflector screen Weather proof aluminum Radiator Tin plate...

Page 3: ...ppropriate standard of the Primary before installation Please contact Kathrein for further information 2 The tightning torque for fixing the connector must be 0 5 1 0 Nm hand tightened The connector should be tightened by hand only Standards EN 60950 1 Safety EN 55022 Emission EN 55024 Immunity ETS 300019 1 4 Environmental Certification CE FCC15 107 class B Scope of supply Integrable Remote Contro...

Page 4: ...al load imposed on an antenna by wind at maximum velocity Wind loads are calculated according to DIN 1055 4 Extraordinary operating conditions such as heavy icing or exceptional dynamic stress e g strain caused by oscillating support structures may result in the breakage of an antenna or even cause it to fall to the ground These facts must be considered during the site planning process The install...

Page 5: ...s The additional nuts supplied are only meant as spares All dimensions in mm and inches 152 5 98 100 3 94 40 1 57 72 2 83 35 1 38 64 2 52 125 4 92 40 1 57 20 25 0 79 0 98 42 115 1 65 4 53 M10 MA 25 Nm M8 MA 20 Nm 20 25 0 79 0 98 Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject ...

Page 6: ...control cables Warning Take care that the iRCU does not fall from the antenna housing when the retaining screw is not tightened The falling iRCU can cause injury or death and may permanently damage equipment For daisy chain operation remove the protection cap and attach a control cable to interconnect with the daisy chain input of the next iRCU Please note Do not remove the protection cap on the d...

Page 7: ...rench according to the manufacturers guidelines Ventilation hole 7 16 female iRCU Description of bottom end cap Single band Antennas with iRCU Dual band Antennas with iRCU Ventilation hole 7 16 female iRCU Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject to change without notic...

Reviews: