Ventilation
The heat generated in the CAP converter is dissipated on
all sides of the housing. When selecting the installation
place, make sure that these sides are not obstructed or
covered. If the device is permanently insuffi ciently venti-
lated, this can have a negative eff ect on the service life of
the device!
Maintain a clearance of at least 20 cm above/below, 2 cm
to each side and 5 cm behind and in front of the device to
allow unobstructed heat dissipation.
Important Instructions for Installation
Danger to life due to high voltage!
Wood screws can come into contact with live parts and cause danger to life through electric shock.
►
Never use the wood screws to install the CAP converter on another electrical appliance (e.g. TV set).
Material damage to the device due to countersunk screws!
►
Never use countersunk screws for installation.
Material damage to the device and malfunction due to overheating!
If the CAP converter is installed on another electrical device (e.g. TV set), the mutual heating can lead to
overheating.
►
Before installing the CAP converter on another electrical device, ask the manufacturer of the device or
refer to the documentation supplied with the device to fi nd out whether this is permissible and, if so,
which aids (screws etc.) are required/may be used.
Using other screws
If the supplied screws cannot be used due to the instal-
lation place or the condition of the installation place,
please refer to the fi gure on the right to select the correct
screws. It shows a cross-section of the screw holes of the
CAP converter. It also specifi es the required characteris-
tics of the fi xing screws that are inserted into the bracket
of the CAP converter, e.g. diameter, type of screw head,
etc.
Material damage due to insuffi cient ventilation!
The device monitors its own operating temperature. Continuous operation of the device above the recom-
mended operating temperature due to insuffi cient ventilation can lead to premature failure of the device.
This is not a warranty/guarantee case!
The CAP converter may only be operated at the recommended operating temperature.
2 cm
20 cm
5 cm
2 cm
5 cm
Minimum
clear
ance