17
Type
MSK 200/S2
MSK 200/M4
MSK 200/ME
MSK 200/MT
Part no.
21710024 (75
Ω
)
21710025 (50
Ω
)
21710026 (75
Ω
)
21710027 (50
Ω
)
21710034 (75
Ω
)
21710035 (50
Ω
)
21710042 (75
Ω
)
21710043 (50
Ω
)
Spectrum analyser
Frequency range
MHz
5-3100
Resolution bandwidth (-3 dB)
kHz
MHz
1, 3, 10, 30, 100, 300
1, 3
Resolution bandwidth (-6 dB)
kHz
9, 25, 50, 120, 200
Video bandwidths
MHz
0.00001-3
Phase noise at 10-kHz carrier spacing
dBc
< -90 (1 Hz), typ. -95 (1 Hz)
Phase noise at 100-kHz carrier spacing
dBc
<-100 (1 dB), typ. -110 (1 Hz)
Dynamic (RBW: 100 kHz)
dB
Type 70
Level measuring range
dB
μ
V
30-130 / -128 (50 Ohm)
Total input power max.
W
0.5
Measurement accuracy
dB
< 1.5
Measurement detector
dB
Max peak, min peak, auto peak, sample, RMS
Return loss (5-dB pre-attenuation)
dB
> 16 (VSWR: 1.35)
Refresh rate
Pic./s
Max. 10
Reference level
dB
μ
V
30-130
Display range
dB
100, 70, 50, 30, 20, 10
Screen resolution
Pixels
Max. 800 x 600/nominal 501 x 401
FM radio receiver
Frequency range
MHz
87.5-108
Channel bandwidth
kHz
300
De-emphasis
μ
s
50/75
Analogue TV receiver
Frequency range
MHz
10-895
Standards
B/G, I, D/K, L/L´, M/N
Colour standards
PAL, SECAM, NTSC
Audio standards
IRT-A2, NICAM, BTSC, EIA-J
Nicam bit error rate
1.0E-9...1.5E-2
Channel bandwidth
MHz
6/7/8
Frequency increment
kHz
50
Video IF bandwidth
According to standard
Audio IF bandwidth
According to standard
Audio de-emphasis
μ
s
50/75
Video output voltage/impedance
Vpp/Ohm
1/75 ± 1 dB
Hum measurement (suppression)
dB
> 50
S/N measurement (evaluated according to
CCIR Rec. 567)
dB
> 55/typ. 57
TECHNICAL APPENDIX