89 of 112
14.8.3 Change Reader Parameter
Change reader parameter
allows to change all reader settings using their r
espective configur
ation IDs.
4
6
1
2
4
5
3
Fig. 52: Expert settings 2: change reader parameter
①
Parameter ID
selects the parameter ID
②
Parameter value
shows or sets the parameter value
The value is either decimal or hexadecimal, it is possible to switch between
dec
and
hex
.
③
Active parameter
set
shows the current active parameter set
④
Get
reads the value of the current parameter set of the reader and shows it at
②
⑤
Set
writes the parameter value (
②
) into the selected parameter ID (
①
)
14.8.4 Select Filter Settings
By means of these settings, it is possible to filter certain tags, e.g. to only read tags with the defined data in the r
espec-
tive memory banks. It is possible to set up to 32 filters.
7
8
9
10
11
12
2
4
5
1
2
3
4
5
6
Fig. 53:
Expert settings 2: select filter settings
①
Filter
selects a filter
②
Target
selects the tag target session
►
Make sure the target matches the session set in
⑲
Fig.
50, p. 88
.
③
Action
selects the action; see also
EPCglobal Gen 2 Specification
(p. 73)
Tip
►
To see the description of an action, hover over the
Action
field.
➯
The description of the action appears in the tooltip:
④
Memory bank
selects the memory bank (
RFU
/
EPC
/
TID
/
User
)
⑤
Save select filter
data to file
saves the select filter data to file
⑥
Load select filter
data to file
loads the select filter data from file
⑦
On
activates or deactivates the select filter
⑧
Bit pointer
sets from which memory addr
ess the filter compar
es the mask data
⑨
Mask length
sets the mask length (0–255)