3-8 OPERATION
_______________________________________________________________________
Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524
Tel: 970-495-0187, Fax: 970-484-9350, Internet: www.ionsources.com
DISCHARGE POWER SUPPLY MANUAL
MODEL DC3005, MODEL 30010, MODEL 15012
Pin
Number
Description
9
Discharge Voltage Setpoint – Input 0 to 5 volts for 0 to maxi-
mum discharge volts.
10
Discharge Current Setpoint – Input 0 to 5 volts for 0 to maxi-
mum amps of discharge current. Also available at pin 22.
11
Common
12
Common.
13
Aux5 volts DC, 200 mA max. Also available at pin 15 and
25.
14
Remote Shutdown, Active Low – Output is disabled when con-
nected to common. The shutdown is deactivated when 5 volts
is applied or no contact is made. Remote shutdown is indicated
on the front panel when activated.
15
Aux5 volts DC, 200 mA max. Also available at pin 13 and
25.
16
Common
17
Common
18
Over Temperature Output – A 5 volt output indicates over tem-
perature (5 k
Ω
source impedance).
19
Discharge Voltage Monitor – Outputs 0 to 5 volts for 0 to maxi-
mum volts discharge voltage.
20
Remote Local Indicator Output – 0 volts = Remote, 5 volts =
Local (5 k
Ω
source impedance). Also available on pin 4.
21
Common
22
Discharge Current Setpoint – Input 0 to 5 volts for 0 to maxi-
mum amps of discharge current. Also available at pin 10.
23
Regulation Mode – A 5 volt output indicates current regulation.
A 0 volt output indicates voltage regulation. 5 k
Ω
source imped-
ance.
24
Common
25
+Aux 5 volts DC, 200 mA max. Also available at pin 13.