INSPECTION AND INSTALLATION 2-3
_______________________________________________________________________
Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524
Tel: 970-495-0187, Fax: 970-484-9350, Internet: www.ionsources.com
DISCHARGE POWER SUPPLY MANUAL
MODEL DC3005, MODEL 30010, MODEL 15012
2.4.3 Electrical-connections to ion source and discharge power supply
Located on the back panel of the Power Supply are two sections of three con-
nectors each for connecting the Discharge Power Supply directly to the ion
source or through a KRI Filament Power Supply. Each terminal is capable of
the full output of the Discharge Power Supply. Multiple outputs are provided
to allow multiple supplies to share connections.
If the Discharge Power Supply was purchased with an Ion Source and Fila-
ment Power Supply, interconnecting cables are provided. Information regard-
ing installation of these connecting cables can be found in the “Ion Source
Filament Cathode Version Controller Manual”.
If the Discharge Power Supply was purchased as a stand alone unit contact
Kaufman & Robinson, Inc. for cabling requirements.
2.4.4 Electrical-AC input
The Power Supply has been designed for 85-285 volts AC input voltage, 50-
60 Hz, single-phase with a maximum current of 28 amps at the lowest line
voltage. A power supply cable has been included with the Power Supply.
This cable has a female plug at one end that corresponds to the male socket
at the rear panel of the Power Supply. The opposite end of this cable has
been intentionally left bare so that the cable may be installed to facility re-
quirements. Electrical connection made from the Discharge Supply Cable to
the AC voltage within the facility should only be made by quali
fi
ed personnel.