1 1 C
0000-9999
0
Corresponding to A/B/C/D pins of ten bit, start and end back tacking
interface under the A/B/C/D digits together constitute the
two digit pin number, each section of pin number 1~99 needle.
1 1 D
0000-9999
0
Corresponding to E/F/G/H pins of ten bit, start and end back tacking
interface under the E/F/G/H digits together constitute the
two digit pin number, each section of pin number 1~99 needle.
1 2 0
0
/
1
/
2
/
3
0
Start back tacking mode
0: touch the pedal, automatic execution start back tacking.
1: the pedal can be arbitrarily stopped to control.
2: the needle stop up position, 119 parameter [CT] time control
action
3: the needle stop down position, 119 parameter [CT] time control
Back tacking
Mode
1 2 1
0
/
1
/
2
0
Start back tacking after operation mode selection:
0: start back tacking after continue sewing
1: start back tacking after automatic stop
2: start back tacking after automatic trimming
1 2 2
0
/
1
0
constant sewing after operation mode selection:
0
:
end back tacking; 1
:
standby (fill needle)
1 2 3
0
/
1
/
2
/
3
0
End back tacking mode:
0
:
touch the pedal, automatic execution start back tacking
1: none
2: the needle stop up position, 119 parameter [CT] time control
action
3: the needle stop down position, 119 parameter [CT] time control
action
1 2 4
0
/
1
/
2
/
3
0
W back tacking mode:
0: start back tacking after continue sewing
1: start back tacking after automatic stop
2: start back tacking after automatic trimming
1 2 5
0
~
99
0
End back tacking last C segment increase needle number
12