3.2 Administrator mode
1
、
Press
key and
key can modify the administrator parameter table.
2
、
The LCD will display
.Type the password for the administrator, the initial password is
0 0 0 0
,
press the corresponding
key and the
key can change the password value;
3
、
Press
key
,
If the password is correct, enter into the administrator parameter setting mode,shown
,
4
、
Press the corresponding
key and
key or
key and
key, select the parameter
and change the corresponding parameter.
5
、
Press
key, exit parameter setting mode, return to sewing mode.
NO.
Range
Default
Description
Comment
2 0 0
0
/
1
/
2
0
Trimming motor operation mode selection:
0
:
flat sewing machine
1
:
interlock machines
(
ordinary flat seaming shearing line: stop to the
needle position after the trimming
)
2
:
The over-lock type: manual trimming
Trimming
Mode
2 0 1
0
~
359
0
Mech. Angle when trimming finished
2 0 2
0
/
1
/
2
/
3
/
4
/
5
/
6
1
Trimming time sequence selection:
0: The
parameter
203 set angle[TS] start trimming, until the
parameter
206 upper needle stop position is reached, then time delay
to [T2] set value.
1: The parameter 203 set angles [TS] start trimming, until the
parameter 204 set [TE] angle.
2: The parameter 203 set angle [TS] start trimming, time delay to the
parameter 206 set [T2] value.
18