2 1 7
1
~
9999
70
Thread wiping/Thread sweeping time delay ms
2 1 8
1
~
999
50
Thread wiping/Thread sweeping recover time ms
2 1 9
0
/
1
0
Thread nipping function selection
0: off
1: on
2 1 A
10-359
120
Thread nipping initial angle
2 1 B
11-359
318
Thread nipping finish angle
2 1 C
0
~
9999
0
Air blow start time delay ms
2 1 D
1
~
9999
50
Air blow duration time ms
2 1 E
11-359
160
Lower angle after foot lifting when thread nipping
2 2 0
200
~
360
360
Stop position after trimming(can implement pull back function after
trimming)
Stop
Mode
2 2 1
0
~
240
0
Reverse angle before sewing start(enhance the ability over thick
material)
2 2 2
0
/
1
0
D axis current lock selection after stop
2 2 3
1
~
3000
300
D axis current lock duration after stop (ms)
2 2 4
0/1/2/3
0
Emergency Stop Mode:
0: Turn off the emergency stop function
1: Emergency stop at any position
2: Emergency stop at upper needle stop position
3: Emergency stop at lower needle stop position
2 2 5
0
~
999
0
Continue stitch No. before emergency stop (according to different
set speed and stitch No., the actual value might be bigger)
2 2 6
0/1
0
Restart after emergency stop:
0: Can not be restart, it’s necessary to restart the power.
1: When the alarm is canceled, can be restarted.
2 2 7
200
~
360
360
Upper needle position adjustment when machine stop mid position
21