The third step, select the required count needle number mode,
transferred to the 152 parameters, can be set to 3, including the
number of needle after press the reset key to cancel the alarm to
P
count; then press
key save and exit.
The fourth step, open the count needle number monitoring function,
P
press
key, then press
key to enter the monitor mode.
The fifth step, adjusted the parameter number to 010, including the
number of needle monitoring function, so that each turn finished stitch,
stitch count is increased by 1.
The sixth step, when the needle reached the upper limit (parameter
151), for example, when the needle reached to 3000
Operation panel display ALA-2, suggesting that the needle number
alarm, show that the needle number has reached 151, the number of
needle set alarm.
P
The seventh step, press
key to cancel the alarm, and re- start
counting, meter needle alarm number still is determined by 152
parameters.