Fast commissioning
B 2 Fast commissioning, the most important aspects in brief
B 2.1 Connecting the inverter
First check whether the mains voltage corresponds to the rated voltage of the device.
Connect the inverter to the mains voltage and to the motor, see Section B 1 Assembly and installation.
The LCD display shows the standard display (frequency, voltage and current) and one of the upper three light
emitting diodes lights up.
B 2.2 Establishing factory default
The standard state of the inverter is the factory default state.
The display shows
Warning W 15 undefined motor
. See Section B 2.3.
If the inverter is to be controlled via remote control, see Section B 2.4 Remote control parameters.
If the inverter was already in operation and is to be configured for another application,
first establish the factory default:
Menu:
Special functions
/
SP3- reset parameter / all parameters
Keys
Display
2 x
!
Special functions
Enter
"
SP1
-
2 x
#
SP3 - reset parameter
Enter
"
Reset parameter - motor parameter
top
#
(1)
Reset parameter - remote control
top
#
Reset parameter - all parameters
Enter
"
P1 - P150 init. YES?
Enter
"
Function: All parameters to factory setting
!
and
$
Stop
simultaneously
Function: reset inverter
(1) If you wish to bring only the parameters of the motor or the remote control to the factory default, select the
corresponding menu option with the keys
#
and
%
.
For special applications, the inverter can be preconfigured by KaVo before delivery. This is evident from the fact
that the parameter sheet (last sheet of these instructions) has been completed and the inverter shows the stan-
dard display (
0 Hz 0V 0,0 A
) in the normal state.