Customer setting
60
Inverter 4452 motor parameters
Customer:
Date:
Motor/spindle:
Official responsible:
Remark :
Sett.-
Description
Display
Use
Unit
Factory
Customer
Prio. P
ASM BLDC BLDCS
setting
setting
Special settings
O
41
Min. motor frequency
f_mot_min
x
x
x
Hz
50
B
42
Max. motor frequency
f_mot_max
x
x
x
Hz
f_mot_nom
O
43
Max. motor voltage
V_mot_max
x
x
x
V
U_mot_nom
B
44
Current limit
I_limit
x
x
x
A~
1.5 * I_nom
O2 46
Rise time
t_rise
x
x
x
s
5.0
O2 47
Delay time
t_fall
x
x
x
s
5.0
O2 48
Delay time at stop
t_stop
x
x
x
s
t_fall
O2 50
Start option (catch)
Motorstart
x
- - -
Normal
O2 51
Start time
t_start
-
x
-
s
without ramp
O2 52
Start current
I_start
- x
-
A~
0.4
O2 53
Start frequency
f_start
- x -
Hz
5
O2 54
Switch-off time WR
t_off
- x -
µs
600
O2 55
DC brake time
t_DC_brake
x
-
-
s
2
O2 56
DC brake current
I_DC_brake
x
- -
A-
1.0
O2 57
Stop current
I_DC_stop
x
x
x
A-
OFF
O2 58
Flag emergency stop at
mains failure
emerg.stop
x
x
x
-
off
B
59
Speed sensor pulse count
emerg.stop
x
x
x -
no
sensor
U/f Table
O
60
Startup voltage
V_start
x
- -
V~
3%
U_nom
O
61
Frequency 1
f1
x
- -
Hz
f_mot_nom
O
62
Voltage 1
V1
x - -
V~
U_mot_nom
O
63
Frequency 2
f2
x - -
Hz
f_mot_nom
O
64
Voltage 2
V2
x
- -
V~
U_mot_nom
O
65
Frequency 3
f3
x
- -
Hz
f_mot_nom
O
66
Voltage 3
V3
x
-
-
V~
U_mot_nom
Control
O
70
Control (U/f. I*R, slip, N)
Control
x
-
-
-
U/f table
O2 71
I*R comp. rise factor
I*R-factor
x
-
-
V/A
off
O2 72
Load comp. rise factor
Loadkomp
.
x
-
-
%
off
O2 73
I*R and load comp. filter time
comp-T-filt
x
-
-
ms
20
O2 75
Slip comp. P-factor
Slipkomp
x
- -
Hz/A
off
O2 76
Slip comp filter time
slip-T_filt
x - -
Hz/A
20
W
77
Current limitation
I-limtr-KP
x
x
x
%
40
W
78
Current limitation
I-limtr-Tn
x
x
x
ms
10
W
79
Voltage control
V-contr-KP
x
x
x
%
20
W
80
Voltage control
V_contr-Tn
x
x
x
ms
10
O3 81
Speed control
N-contr-KP
x
x
x
%
50
O3 82
Speed control
N-contr-Tn
x
x
x
ms
250
O3 83
Speed control
N-contr-Tv
x
x
x
ms
30
O3 84
Speed control
N-con-T_fil
x
x
x
ms
200
Monitoring:
B
85
Sensor type
Motor prot
x
x
x
-
off
O
86
Resistance
R_protect
x
x
x
ohm
1200
Nominal motor data: (according to rating plate)
E
90
Motor design
motortype
x
x
x
-
no motor
E
91
Nominal frequency
f_mot_nom
x
x
x
Hz
50
E
92
Nominal voltage
V_mot_nom
x
x
x
V
30
E
93
Nominal current
I_mot_nom
x
x
x
A
1.0
E
94
cos. phi
cos phi
x
x
x
%
85
E
96
Number of poles
no.of poles
x
x
x
-
2
Setting priority:
E = Necessary, minimum input,
B = required according to mode,
O =set for optimization (opt level)
W = best left at factory setting