background image

15

EWL 70, 120.

Wir, We, Nous, Nosotros, Noi, Wij, Nós, Vi,  Vi, Me, Vi,

KaVo ELEKTROTECHNISCHES WERK GmbH
Wangener Str. 78
D-88299 Leutkirch im Allgäu

erklären, dass das Produkt

Abzugschrank mit Gebläse type 70, 120

declare that the product

Fume cupboard with fan type 70, 120

déclarons que le produit

Hotte fermée avec ventilateur type 70, 120

declaramos que el producto

Abductor con ventilador type 70, 120

dichiariamo che il nostro prodotto

Cappa con motore aspirante type 70, 120

verklaren dat het product
declaramos que o produto
förklarar att produkten
erklærer, at produktet
ilmoitamme, että tuote
erklærer, at produktet

auf das sich diese Erklärung bezieht, mit den wesentlichen Schutzanforderungen gemäß den Bestimmungen der Richtlinie(n) übereinstimmt.
to which this declaration relates conforms to the essential safety requirements according to the provisions of Directive(s).
auquel se réfère cette déclaration, est conforme aux exigences essentielles de protection conformément aux dispositions de la/ des Directive(s).
al lo cual se refiere esta declaración, coincide con las esenciales exigencias de protección según las determinaciones de la(s) norma(s).
a cui si fa riferimento in questa dichiarazione, è conforme alle misure di sicurezza secondo le direttive delle norm.
waarop deze verklaring betrekking heeft, overeenstemt met de meest essentiële veiligheidseisen volgens de bepalingen van de richtlijn(en) voldoet.
ao qual se refere esta Declaração, coincide com as exigências fundamentais de segurança segundo as determinações da(s) norma(s).
som denna förklaring hänför sig till överensstämmer med de väsentliga skyddskraven enligt bestämmelserna i direktiven.
som denne erklåring omhandler, opfylder de væsentlige beskyttel-seskrav i bestemmelserne i de f

ø

lgende direktiver.

johon tässä ilmoituksessa viitataan, on direktiivien määräysten tärkeimpien turvallisuusvaatimuksien mukainen.
som denne erklåringen gjelder, er i overensstemmelse med de vesentlige vernekravene if

ø

lge bestemmelsene i retningslinjene.

98/37/EWG

(Maschinenschutzrichtlinien)

Zur Beurteilung des Erzeugnisses wurden folgende Normen oder normativen Dokumente angewandt:
The following standards or normative documents were used for assessing the product:
Les normes ou autres documents normatifs suivants sont utilisés pour le jugement de ce produit :
Para la evaluación del producto se aplicaron las siguientes normas o documentos norma:
Per la valutazione del prodotto sono state applicate le seguenti normative o altri documenti normat:
Ter beoordeling van dit product is gebruik gemaakt van de volgende normen of normatieve documenten:
Para a avaliação do produto foram aplicadas as seguintes normas ou documentos normativos:
För bedöming av produkten har följande normer eller normativa dokument tillämpats:
De f

ø

lgende Normer eller normative dokumenter blev anvendt ved bed

ø

mmelsen af produktet:

Tuotteen arvioimisessa käytettiin seuraavia standardeja ja standardeista määrääviä asiakirjoja:
F

ø

lgende standarder eller andre normative dokumenter er benyttet i vurderingen av dette produktet:

EN 61010

/Teil 1 + A2 Sicherheitsbestimmungen für Meß-, Steuer-, Regel- und Laborgeräte

EN 55104

/Elektromagnetische Verträglichkeit

Leutkirch, 27.09.2000

M.Mohr 

-Managing Director-

Konformitätserklärung; 

Declaration of conformity;             KE42 

Déclaration de conformité; 

Declaración de conformidad; 

CE-Dichiarazione di conformitá; 

EU-conformiteitsverklaring 

Declaração de conformidade;

EU-konformitetsförklaring

EU-Konformitetserklæring;

EY Vaatimustenmukaisuusvakuutus

EU-Konformitetserklæring;

çàÿâëÿåì, ÷òî ïðîäóêò

EC-Êîíôîðìíîñòü

Ìû,

î êîòîðîì èäåò ðå÷ü â äàííîì çàÿâëåíèè, ñîîòâåòñòâóåò îñíîâíûì òðåáîâàíèÿì íèæåèçëîæåííûõ ïðåäïèñàíèé

Äëÿ îöåíêè ïðîäóêòà èñïîëüçîâàëèñü ñëåäóþùèå íîðìû è íîðìàòèâíûå äîêóìåíòû:

Summary of Contents for EWL 70

Page 1: ...Operating instructions EWL 70 120 Always on the safe side...

Page 2: ...KaVo Elektrotechnisches Werk GmbH Wangener Stra e 78 D 88299 Leutkirch Tel 0 75 61 86 150 Fax 0 75 61 86 265...

Page 3: ...5 A 5 2 Assembly of the rinsing panel on wall brackets 5 A 5 3 Fitting the water inlet 6 A 5 4 Fitting the water outlet 7 A 5 5 Mounting and connecting the extraction fan 8 A 5 6 Cupboard lightning 8...

Page 4: ...only by quali fied technical personnel In the event of modifications by third par ties the approvals become null and void KaVo recommends using only original spare parts for operation and for repair A...

Page 5: ...of screws Fume cupboard type 120 with fan on wall brackets consisting of 1 fumecupboard 120 1 rinsing panel 120 1 fan 1 outlet 1 inlet 2 brackets 1 set of screws Fume cupboard type 70 with fan on leg...

Page 6: ...nto account Overall height minimum 2240 mm Minimum width of type 70 710 mm Minimum width of type l20 1210 mm Minimum suction capacity under consideration of the exhaust duct for Type 70 300 m 3 h Type...

Page 7: ...at least 5 mm from the wall for the installation of the fume cupboard Possible wall unevenness must be taken into account Level the rinsing panel by means of adjusting screws A 5 2 Assembly of the ri...

Page 8: ...cable place it in the recess at the front on the left hand side A 5 3 Fitting the water inlet Insert the inlet tube with washer in the rinsing panel screw together tightly with nut and washer Apply s...

Page 9: ...nnection tightly with the nut Screw the connecting piece with the spigot and washer firmly together with the outlet connection Insert the riser draining pipe in the outlet connection The link with the...

Page 10: ...ly cable into the socket outlet of the control unit A 5 6 Cupboard lightning The fume cupboard is delivered without incandescent lamp if the voltage of the local power supply differs from 220V Unscrew...

Page 11: ...xcluding flap Example 38 m straight pipe 38 m 8 bends equivalent to 4 m each 32 m 1 outdoor air damper 4 m Total 74 m With diagramm A these 74 m result in a pipe diameter of at least 150 mm and a leve...

Page 12: ...ional elements 1 Fume cupboard 2 Safety screen 3 Pipe fan 4 Extraction fan switch 5 Light switch 6 Lightning 7 Cover glass 8 Cable pull 9 Counterweight 0 Cable gland q Rinsing panel w Inlet stop cock...

Page 13: ...ld plating bath etc becomes readily accessible to work with Finished parts must be thoroughly rinsed in the tank The manufacturer s safety instructions must be strictly observed when handling acids an...

Page 14: ...rt of the equipment Intensely vibrating extraction fan Cause a Soiled extraction fan b Defective bearings Remedy a Clean the extraction fan b Exchange the extraction fan Extraction fan is not rotating...

Page 15: ...0 mm Height with open safety 2240 mm Depth 620 mm Extraction fan connection 200 mm Suction capacity with external pressure V m3 h p Pa 680 0 Level I 500 70 300 170 830 0 Level II 500 170 300 210 950 0...

Page 16: ...out repairs free of charge KaVo EWL accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear improper handling cleaning or maintenance...

Page 17: ...erkl ring omhandler opfylder de v sentlige beskyttel seskrav i bestemmelserne i de f lgende direktiver johon t ss ilmoituksessa viitataan on direktiivien m r ysten t rkeimpien turvallisuusvaatimuksien...

Page 18: ...1046 0 223 2292 0 659 0742 0 659 7342 0 658 4452 0 256 1050 0 659 8212 0 221 3119 0 659 0501 100 110 V 0 659 0491 120 V 0 659 0461 220 240 V 0 226 4233 T2A 100 120 V 0 223 2738 T0 8A 220 240 V 0 659 2...

Page 19: ...0541 0 692 3481 0 659 0541 0 658 4452 0 256 1050 0 221 3119 0 659 8212 0 223 2329 0 223 2741 0 223 1046 0 223 1026 1 000 4656 0 223 0045 1 000 9939 0 223 0041 0 223 0514 0 223 2327 0 659 0742 0 659 73...

Page 20: ...9 01 GB 04 07 D D 8 88 82 29 99 9 L LE EU UT TK KI IR RC CH H T Te el le ef fo on n 0 07 75 56 61 1 8 86 6 1 15 50 0 F Fa ax x 0 07 75 56 61 1 8 86 6 2 26 65 5 I In nt te er rn ne et t w ww ww w k ka...

Reviews: