A 1.2 Important information

The instructions for use should be
read by the user before starting up the

unit for the first time, in order to avoid
incorrect operation and other damage. If
other language versions are required, please
request these from your responsible KaVo
agent. Duplication and distribution of the
instructions for use (IU) require KaVo's
prior consent.

All technical data, information and proper-
ties of the product described in the IU cor-
respond to the state on going to press.

Modifications and improvements to the
product as a result of new technical devel-
opments are possible.

This does not imply any right to retrofitting
of existing units.

KaVo assumes no responsibility for damage
arising through:

• external influences (poor quality of the

media or inadequate installation)

• use of incorrect information
• improper use
• improperly performed repairs.

Repair and maintenance work - apart from
the activities described in these instructions
for use - may be performed only by quali-
fied technical personnel.

In the event of modifications by third par-
ties, the approvals become null and void.
KaVo recommends using only original
spare parts for operation and for repair.

A 1.3 Precautions

Safe operation and protection of the unit are
ensured only through proper use in accor-
dance with the instructions for use and
using the tools approved for the purpose.
The following should also be observed:

• the work safety regulations,
• the accident prevention regulations.

Each time before switching on, check the

set speed.

■ 

Observe the permissible maximum speed

and maximum pressure of the tools
(according to tool manufacturer's
instructions).

According to these provisions, it is the
user’s obligation:

•  to use only fault-free operating materials
•  to ensure that it is used for the correct 

purpose

A 1 User information

A 1.1 Meaning of the pictograms

Situations where failure to follow the
instructions may lead to danger,

damage to material or operating faults.

Important information for operator
and engineer.

Automatic mode
Automatic sequence

Close, screw in, 
fasten, etc.

Open, release, loosen

+   more, higher

-  less, lower

Continuous operation

Time, time sequence

Disconnect mains plug

Summary of Contents for EWL 70

Page 1: ...Operating instructions EWL 70 120 Always on the safe side...

Page 2: ...KaVo Elektrotechnisches Werk GmbH Wangener Stra e 78 D 88299 Leutkirch Tel 0 75 61 86 150 Fax 0 75 61 86 265...

Page 3: ...5 A 5 2 Assembly of the rinsing panel on wall brackets 5 A 5 3 Fitting the water inlet 6 A 5 4 Fitting the water outlet 7 A 5 5 Mounting and connecting the extraction fan 8 A 5 6 Cupboard lightning 8...

Page 4: ...only by quali fied technical personnel In the event of modifications by third par ties the approvals become null and void KaVo recommends using only original spare parts for operation and for repair A...

Page 5: ...of screws Fume cupboard type 120 with fan on wall brackets consisting of 1 fumecupboard 120 1 rinsing panel 120 1 fan 1 outlet 1 inlet 2 brackets 1 set of screws Fume cupboard type 70 with fan on leg...

Page 6: ...nto account Overall height minimum 2240 mm Minimum width of type 70 710 mm Minimum width of type l20 1210 mm Minimum suction capacity under consideration of the exhaust duct for Type 70 300 m 3 h Type...

Page 7: ...at least 5 mm from the wall for the installation of the fume cupboard Possible wall unevenness must be taken into account Level the rinsing panel by means of adjusting screws A 5 2 Assembly of the ri...

Page 8: ...cable place it in the recess at the front on the left hand side A 5 3 Fitting the water inlet Insert the inlet tube with washer in the rinsing panel screw together tightly with nut and washer Apply s...

Page 9: ...nnection tightly with the nut Screw the connecting piece with the spigot and washer firmly together with the outlet connection Insert the riser draining pipe in the outlet connection The link with the...

Page 10: ...ly cable into the socket outlet of the control unit A 5 6 Cupboard lightning The fume cupboard is delivered without incandescent lamp if the voltage of the local power supply differs from 220V Unscrew...

Page 11: ...xcluding flap Example 38 m straight pipe 38 m 8 bends equivalent to 4 m each 32 m 1 outdoor air damper 4 m Total 74 m With diagramm A these 74 m result in a pipe diameter of at least 150 mm and a leve...

Page 12: ...ional elements 1 Fume cupboard 2 Safety screen 3 Pipe fan 4 Extraction fan switch 5 Light switch 6 Lightning 7 Cover glass 8 Cable pull 9 Counterweight 0 Cable gland q Rinsing panel w Inlet stop cock...

Page 13: ...ld plating bath etc becomes readily accessible to work with Finished parts must be thoroughly rinsed in the tank The manufacturer s safety instructions must be strictly observed when handling acids an...

Page 14: ...rt of the equipment Intensely vibrating extraction fan Cause a Soiled extraction fan b Defective bearings Remedy a Clean the extraction fan b Exchange the extraction fan Extraction fan is not rotating...

Page 15: ...0 mm Height with open safety 2240 mm Depth 620 mm Extraction fan connection 200 mm Suction capacity with external pressure V m3 h p Pa 680 0 Level I 500 70 300 170 830 0 Level II 500 170 300 210 950 0...

Page 16: ...out repairs free of charge KaVo EWL accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear improper handling cleaning or maintenance...

Page 17: ...erkl ring omhandler opfylder de v sentlige beskyttel seskrav i bestemmelserne i de f lgende direktiver johon t ss ilmoituksessa viitataan on direktiivien m r ysten t rkeimpien turvallisuusvaatimuksien...

Page 18: ...1046 0 223 2292 0 659 0742 0 659 7342 0 658 4452 0 256 1050 0 659 8212 0 221 3119 0 659 0501 100 110 V 0 659 0491 120 V 0 659 0461 220 240 V 0 226 4233 T2A 100 120 V 0 223 2738 T0 8A 220 240 V 0 659 2...

Page 19: ...0541 0 692 3481 0 659 0541 0 658 4452 0 256 1050 0 221 3119 0 659 8212 0 223 2329 0 223 2741 0 223 1046 0 223 1026 1 000 4656 0 223 0045 1 000 9939 0 223 0041 0 223 0514 0 223 2327 0 659 0742 0 659 73...

Page 20: ...9 01 GB 04 07 D D 8 88 82 29 99 9 L LE EU UT TK KI IR RC CH H T Te el le ef fo on n 0 07 75 56 61 1 8 86 6 1 15 50 0 F Fa ax x 0 07 75 56 61 1 8 86 6 2 26 65 5 I In nt te er rn ne et t w ww ww w k ka...

Reviews: