Instructions for use SMARTmatic S80 K - 1.011.6771

3 Description of the product | 3.3 Transportation and storage conditions

3.3 Transportation and storage conditions

NOTICE

Startup after refrigerated storage.
Malfunction.

▶ Prior to startup, strongly refrigerated products must be allowed to warm up to a

temperature of 20 °C to 25 °C (68 °F to 77 °F).

Temperature: -20°C to +70°C (-4°F to +158°F)

Relative humidity: 5% RH to 95% RH absence of condensation

Air pressure: 700 hPa to 1060 hPa (10 psi to 15 psi)

Protect from moisture

9 / 24

Summary of Contents for SMARTmatic S80 K

Page 1: ...Instructions for use SMARTmatic S80 K 1 011 6771 ...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com ...

Page 3: ...ting 13 6 2 1 Replacing the O rings 13 7 Reprocessing steps in accordance with ISO 17664 14 7 1 Preparations at the site of use 14 7 2 Cleaning 14 7 2 1 Manual external cleaning 14 7 2 2 Automated external cleaning 14 7 2 3 Manual internal cleaning 14 7 2 4 Automated internal cleaning 15 7 3 Disinfection 15 7 3 1 Manual external disinfection 16 7 3 2 Manual internal disinfection 16 7 3 3 Automated...

Page 4: ...p This document is intended for dentists and their assistants The startup section is also intended for service technicians General marks and symbols Refer to the chapter on Safety Warning symbol Important information for users and service technicians Action request CE mark European Community A product bearing this mark meets the re quirements of the applicable EC directive Can be steam sterilised ...

Page 5: ...ns for use SMARTmatic S80 K 1 011 6771 1 User instructions CAUTION In cases which if not prevented could lead to minor or moderate injury NOTICE In cases which if not prevented could lead to material damage 5 24 ...

Page 6: ...ury to soft tissue do not continue treatment in the oral cavity with instruments driven by compressed air Use gloves or finger guard whenever you test insert and remove the tool 2 2 Technical condition A damaged device or components could injure patients users and third parties Only operate devices or components if they are undamaged on the outside Check that the device is working properly and is ...

Page 7: ... in jure the patients the users or third parties Make sure that the user has read and understood the instructions for use Only employ the device if the user has the appropriate medical training Observe national and regional regulations The improper use of the device could lead to burns or injuries Never touch soft tissue with the handpiece head or instrument cover After treatment place the medical...

Page 8: ...use According to these provisions this medical device may only be used for the described application by a properly trained user You need to comply with the following the applicable health and safety regulations the applicable accident prevention regulations these Instructions for use According to these regulations the user is required to to only use equipment that is operating correctly adhere to ...

Page 9: ...nditions NOTICE Startup after refrigerated storage Malfunction Prior to startup strongly refrigerated products must be allowed to warm up to a temperature of 20 C to 25 C 68 F to 77 F Temperature 20 C to 70 C 4 F to 158 F Relative humidity 5 RH to 95 RH absence of condensation Air pressure 700 hPa to 1060 hPa 10 psi to 15 psi Protect from moisture 9 24 ...

Page 10: ... the product in appropriate manner Infection hazard Reprocess and sterilise the product and accessories before disposal NOTICE Damage from soiled and moist cooling air Contaminated and moist cooling air can cause malfunctions Make sure that the supply of cooling air is dry clean and uncontaminated accord ing to EN ISO 7494 2 NOTICE Damage to the contra angle handpiece caused by spray air and spray...

Page 11: ...device while pressing the foot switch Lightly spray O rings on motor coupling with KaVo Spray Place the medical device on the motor coupling and lock it into place Pull on the medical device to make sure that it is securely affixed to the coupling 5 2 Removing the medical device Unlock the medical device from the motor coupling by twisting it slightly and then pulling it along its axis 5 3 Inserti...

Page 12: ...aft and chuck system reduction of the service life of tool and chuck system Do not operate the tool at a higher speed than recommended by the manufac turer NOTICE Use of dental burs or diamond grinders with worn or damaged shafts Material damage to the chuck system tool is difficult or impossible to remove from the chuck system Do not use dental burs or diamond grinders with damaged or worn shafts...

Page 13: ... working Service the medical device When the speed drops or is uneven Service the medical device An O ring is missing on the motor coupling Replace O ring See also 2 Instructions for use of motor 6 2 Troubleshooting 6 2 1 Replacing the O rings CAUTION Hazard from improper care of the O rings Functional problem or complete failure of the medical device Do not use Vaseline or other grease or oil Not...

Page 14: ...ic device Malfunction and material damage Clean manually or in a washer disinfector only 7 2 1 Manual external cleaning Accessories required Tap water 30 o C 5 o C 86 o F 10 o F Brush e g medium hard toothbrush Brush off under flowing tap water 7 2 2 Automated external cleaning KaVo recommends washer disinfectors in compliance with EN ISO 15883 1 that are operated with alkaline cleaning agents The...

Page 15: ...ng agents The validations were conducted with the VARIO TD program the cleaning agent neodisher MediClean and the neutralisation agent neodisher Z For program settings as well as cleansers and disinfectants to be used please refer to the Instructions for Use of the thermodisinfector In order to prevent damage to the medical device due to residual fluid make sure that the inside and outside of the ...

Page 16: ...ith respect to the compatibility of materials e g WL cid made by ALPRO Immediately after internal disinfection lubricate the KaVo medical device with care agents from the KaVo care system 7 3 3 Automated external and internal disinfection KaVo recommends washer disinfectors in compliance with EN ISO 15883 1 that are operated with alkaline cleaning agents The validations were conducted with the VAR...

Page 17: ...re wear and reduced product service life Service regularly with suitable agents Note KaVo guarantees the proper function of KaVo products only if the care products lis ted as accessories are used since these were tested for proper use on our products 7 5 1 Servicing with KaVo Spray KaVo recommends servicing the product as part of the reprocessing after each use i e after each cleaning disinfection...

Page 18: ...sure for the interior cleaning of inor ganic residues and optimum care no validated cleaning of the interior in accordance with German RKI requirements KaVo recommends servicing the product as part of the reprocessing after each use i e after each cleaning disinfection and before each sterilisation Remove the dental bur or diamond grinder Service the product See also 2 Instructions for use KaVo QU...

Page 19: ...three seconds until the spray canister control LED flashes three times consecutively ð The device is in chuck service mode Remove the service coupling of the chuck from the side hatch of the QUATTRO care PLUS and attach it to coupling service point four on the far right A MUL TIflex adaptor must be mounted there Press the handpiece together with the guide bush of the chuck to be serviced against t...

Page 20: ...amage to product Immediately remove the product from the steam steriliser after the sterilisation cycle The KaVo medical device has a maximum temperature resistance up to 138 280 4 F Select a suitable procedure depending on the available autoclave from the following sterilisation processes Autoclave with three times pre vacuum at least 3 minutes at 134 C 1 C 4 C 273 F 1 6 F 7 4 F Steriliser using ...

Page 21: ... Cleanpac 10 units 0 411 9691 Cellulose pad 100 units 0 411 9862 Spray head INTRA KaVo Spray 0 411 9911 INTRA service coupling 1 009 6143 Material summary Mat No Adapter INTRAmatic CLEANspray and DRYspray 1 007 1776 KaVo CLEANspray 2110 P 1 007 0579 KaVo DRYspray 2117 P 1 007 0580 KaVo Spray 2112 A 0 411 9640 ROTAspray 2 2142 A 0 411 7520 QUATTROcare plus Spray 2140 P 1 005 4525 21 24 ...

Page 22: ...equences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calcination or corrosion con taminated air or water supplies or chemical or electrical factors deemed abnormal or impermissible in accordance with KaVo s instructions for use or other manufacturer s instructions The warranty granted...

Page 23: ......

Page 24: ...1 010 0599 sö 20180120 2 en ...

Reviews: