Technical Data: 

Lens correction (correction of defective vision) ± 20 dpt.. Angle of vision ± 6°. Aspherical lens for optimal imaging 

quality. Aspherical condenser for optimal illumination. Strong vacuum lamp 2.5 V / 0.81 W.

Further instructions, maintenance, storage: 

When used and stored properly, this instrument will serve you reliably for many years.

Guarantee: 

When used under normal circumstances and with attention to these instructions (the user’s manual) we guarantee this 

product for two years after the date of purchase. Should you need further information or should your instrument require repair, please 
contact your dealer!

Manufacturer: 

KaWe

  Warning instructions: 

Never immerse the ophthalmoscope in any liquid and prevent any liquid from penetrating into the hou-

sing! The ophthalmoscope is not intended for use during operations and therefore simple cleaning and/or disinfection with an alcohol-
base surface disinfecting agent is sufficient. Do not use abrasive cleaning agents! The ophthalmoscope cannot be sterilized.

Limitation of reuse preparation: 

No special requirements. We suggest that the instrument be re-prepared for use as soon as possible 

after it has been used.

Instructions:

Workstation: 

Remove surface impurities with a paper towel or throw-away cloth. 

Storage and transport: 

No special requirements.

Cleaning preparation: 

No special requirements. Must not be disassembled.

Manual cleaning: 

In order to avoid contact with dirt and dust, always store the ophthalmoscope in its packaging. A damp, soft and 

lint-free cloth can be used to clean the instrument. To disinfect the instrument, a cloth dampened in alcohol can be used.

Automatic cleaning: 

Automated cleaning is not possible.

Disinfection:

 Not required

Maintenance: 

Remove and replace damaged parts. 

Check and performance test: 

Check all movable parts such as shutter and lens correction wheels as well as plug-in connections for 

smooth operation. Turn on the instrument.  

Packaging: 

Singly in bag or carton

Sterilization: 

Not a chirurgic instrument, sterilisation neither necessary nor possible

Storage: 

No special requirements.

Additional information: 

No special requirements.

   Disposal: 

Please dispose of used batteries and accumulators in accordance with legal regulations. Li-Ion / NiMH

Contact with the manufacturer:

 Address or phone number of the dealer or dial the 49-7141-68188-0.

For further questions or in case of necessary repair work, please contact your dealer!

7

Explanation of the symbols:

M

anufacturer

Warning

Date of manufacture

Meets relevant EU standards

Please heed the user’s manual

Separate disposal of electric and 
electronic instruments

Summary of Contents for EUROLIGHT E10/2,5 V

Page 1: ...E30 2 5V KaWePICCOLIGHT E50 2 5V Ophthalmoskop KaWeEUROLIGHT E10 2 5V KaWeEUROLIGHT E30 2 5V KaWePICCOLIGHT E50 2 5V Ophtalmoscope KaWeEUROLIGHT E10 2 5V KaWeEUROLIGHT E30 2 5V KaWePICCOLIGHT E50 2 5...

Page 2: ...erweiterndeMedikamenteverwendetwerdenkann Allerdingsistindiesem Fall das Gesichtsfeld des Patienten eingeschr nkt Ungeeignete Anwendung Kontraindikation der Produkte Eineandereoderdar berhinausgehende...

Page 3: ...es Instrumentenkopfes in den Batterie Handgriff 8 Ein und Ausschalten am Schiebeschalter 9 Batteriewechsel bei ausgeschraubtem Instrumentenkopf Mit dem Korrektionslinsenrad kann eine Fehlsichtigkeit v...

Page 4: ...Papiertuchentfernen Aufbewahrung undTransport Keine besonderen Anforderungen Reinigungsvorbereitung KeinebesonderenAnforderungen Zerlegungnichterforderlich Reinigung manuell Zur Vermeidung von Verschm...

Page 5: ...In this case the patient s field of sight is limited however Unsuited use Contraindication of the products Any use other than that described here is not in accordance with the intended use of the unit...

Page 6: ...firmly onto the battery handle 8 Turn on and off using the sliding switch 9 Change the batteries by unscrewing the instrument head On all models the lens correction wheel can be used by the patient a...

Page 7: ...a paper towel or throw away cloth Storage and transport No special requirements Cleaning preparation No special requirements Must not be disassembled Manual cleaning In order to avoid contact with dir...

Page 8: ...d observation est limit Utilisation inappropri e Contre indication des produits Toute autre utilisation est consid r e non conforme Pour l alimentation en courant n utiliser que la poign e livr e Dans...

Page 9: ...piles AA Mignon 1 5V Visser la t te de l instrument dans la poign e piles 8 Pour allumer et teindre l appareil se servir du commutateur coulisse 9 Pour changer les piles d visser la t te de l instrum...

Page 10: ...ier Conservation et transport Aucune mesure particuli re n est n cessaire Pr paration du nettoyage Aucune condition particuli re le d montage n est pas n cessaire Nettoyage manuel Pour viter l encrass...

Page 11: ...tato Uso inappropriato Controindicazioni del prodotto Ogni utilizzo che esuli da dette applicazioni viene considerato come non conformeallenormeprescritte Perl alimentazionedicorrenteutilizzaresolamen...

Page 12: ...ico 10 KaWe PICCOLIGHT modello E50 2 batterie AA stilo 1 5V Avvitamentodellatestinadellostrumentonelmanicoportabatterie 8 Inserimentoedisinserimentotramitel interruttoreascorrimento 9 Cambio batterie...

Page 13: ...are Preparazione alla pulitura Nessuna indicazione particolare non necessario scomporre lo strumento Pulituramanuale Ondeevitarechel oftalmoscopiosisporchiesiimpolveri tenerlosemprenell appositoimball...

Page 14: ...casos es limitado Utilizaci n inapropiada Contraindicaci n de los productos Cualquier otra utilizaci n distinta a la aqu indicada se considera como no conforme a su finalidad prevista Para el suminist...

Page 15: ...OLIGHT E50 2 pilas de tipo AA Mignon 1 5V Enrosque la cabeza del oftalmoscopio en el mango a pilas 8 Para encender y apagar el aparato utilice el conmutador corredizo 9 Paracambiarlaspilasdesenrosquel...

Page 16: ...vaci n y transporte No se requieren medidas especiales Preparaci n para la limpieza No se requieren medidas especiales no es necesario desmontar el instrumento Limpieza manual Mantenga siempre el ofta...

Page 17: ...pria Contra indica odosprodutos Umoutrocampodeaplica oquen osejaoacimadescrito considerado como n o de acordo com a sua finalidade Utilize unicamente o cabo fornecido como fonte de energia O fabricant...

Page 18: ...rrar o interruptor para a direita at ao ponto inicial 9 Tome particular aten o a que o interruptor encaixe na posi o de desligamento 9 Para substituir as pilhas desenroscar a tampa de fecho do fundo 1...

Page 19: ...h requisitos especiais Recomendamos realizar o reprocessamento de um instrumento logo ap s a sua aplica o Instru es Local de trabalho Eliminar sujidades na superf cie com um pano para uso simples toa...

Page 20: ...G KaWe Fundus KaWe KaWe EUROLIGHT E10 2 5 1 2 20 3 4 5 6 7 8 KaWe EUROLIGHT E30 2 5 1 2 20 3 4 5 6 7 8 9 10 KaWe EUROLIGHT E10 2 5 B KaWe EUROLIGHT E30 2 5 B KaWe PICCOLIGHT E50 2 5 B O 1 7 5 10 2 9 8...

Page 21: ...KaWe 2 5 KaWe EUROLIGHT E10 KaWe EUROLIGHT E30 KaWe EUROLIGHT E10 2 C Baby 1 5 8 9 9 9 9 10 KaWe EUROLIGHT E30 2 C Baby 1 5 8 9 9 9 9 10 KaWe PICCOLIGHT E50 2 AA Mignon 1 5 8 9 KaWe KaWe EUROLIGHT E3...

Page 22: ...22 20 6 2 5 0 81 2 KaWe Li Ion NiMH 49 7141 68188 0...

Page 23: ...USA con 6 diaframmi Oftalmoscopio versi n UE EE UU con 6 diafragmas Oftalmosc pio Vers o da UE Vers o dos EUA com 6 diafragmas E 6 Weitere Ophthalmoskope auf Anfrage Further ophthalmoscopes available...

Page 24: ...QM 1 115B 2011 04 KIRCHNER WILHELM GmbH Co KG Eberhardstr 56 71679 Asperg Germany Zentrale Switchboard Fon 49 7141 68188 0 Fax 49 7141 68188 11 eMail info kawemed de Internet www kawemed de...

Reviews: