www.kawemed.com
18
Dear Customer, thank you for choosing a KaWe product. Our
products are known for their high quality and longevity. This
KaWe product fulfils the requirements of EC Directive 93/42/
EWG (Medical Devices Directive). We assume no liability for
improper or inadequate use of this device, or if the device is
not checked before use. Please read these instructions carefully
and completely before use and follow the maintenance
instructions.
1. Application
The SwiSto3 is used in medical facilities and in the home by
healthcare professionals as well as by non-professionals.
2. Intended use
The SwiSto3 iontophoresis set is designed to treat intense foot,
hand and underarm perspiration. This is a proven and tested
anti-perspiration system that uses tap water iontophoresis.
A reduction in perspiration can be observed after as few as
approx. 15 – 20 treatments, each lasting 20 to 30 minutes.
Treatment is only to be administered two to three times per
week. A suitable treatment plan based on individual level of
hyperhidrosis is to be determined by a doctor.
3. Scope of delivery: SwiSto3
1 x SwiSto3 iontophoresis device
2 x water trays
2 x plate electrodes (150 x 220 mm) incl. cable
2 x electrode sponge pads
1 x charging plug
4. Accessories
2 x plate electrodes with sponge pockets for underarm
perspiration treatment,
2 x replacement sponge pockets (ca. 90 x 110 mm)
User‘s Manual
5. Manufacturer responsibility
The manufacturer only assumes responsibility for the safety,
reliability and efficient operation of the SwiSto3 iontophoresis
device if:
1) repairs, modifications, readjustments or enhancements are
performed by the manufacturer or by a person authorised by
the manufacturer and
2) the electrical system installed in the treatment room meets
the requirements of ICE-stipulations and
3) the SwiSto3 iontophoresis device is used in accordance with
the instructions given in the user‘s manual.
The manufacturer is not liable for damages resulting from
improper use. Only use the plate electrodes and connection
cables supplied by KaWe and/or the original KaWe-brand
spare parts and accessories.
6. Symbol key
Power button
Anode
Cathode
Increase current
Decrease current
Menu button for selecting settings
Continuous current
Pulsed current
Treatment time
Battery symbol
Electromagnetic field warning
Charge symbol
ENGLISH
Summary of Contents for SwiSto3
Page 3: ...Deutsch English Fran ais Italiano Espa ol Portugu s 6 17 18 29 30 41 42 53 54 65 66 77 78 89...
Page 4: ......
Page 79: ...www kawemed com 79 BF DIN IEC 601 1 VDE 0750 1 LOT IP41 1 0 REF SN 7 2 KaWe 1...
Page 80: ...www kawemed com 80 0 2 KaWe 4 8 800...
Page 86: ...www kawemed com 86 SwiSto3 CISPR 11 1 SwiSto3 CISPR 11 B SwiSto3 IEC 61000 3 2 A IEC 61000 3 3...
Page 90: ......
Page 91: ......