9.2 

Return Policy 

If the Kaye HTR-420 malfunctions within the warranty period, the following procedures must be 

completed. 

1.  Contact the local Customer Support Center, listed below, and provide the full details of the 

problem and the serial number of the unit. If the nature of the problem indicates the need 

for factory service, Amphenol Advanced Sensors will provide you with a “RETURN 

AUTHORIZATION” number and shipping instructions for the return of the unit to the 

nearest service center.  

2.  If Amphenol Advanced Sensors instructs you to send the unit to a service center, it must be 

shipped prepaid to the authorized repair center indicated in the shipping instructions. 

3.  Upon receipt, Amphenol Advanced Sensors evaluates the unit to determine the cause of 

the malfunction. 

 
Then one of the following courses of action will be taken: 

  If the malfunction is covered under the terms of the warranty, the unit will be repaired at no 

cost to the owner and returned. 

  If Amphenol Advanced Sensors determines that the malfunction is not covered under the 

terms of the warranty, or if the warranty has expired, an estimate for the cost of the repairs 

at standard rates will be provided. Upon receipt of the owner’s approval to proceed, the unit 

will be repaired and returned. 

 

Summary of Contents for HTR-420

Page 1: ...Kaye HTR 420 Dry Block User Manual M5450 Rev A October 2020...

Page 2: ...Kaye HTR 420 Dry Block User Manual M5450 Rev A October 2020 www kayeinstruments com 2020 Amphenol Thermometrics Inc All rights reserved Technical content subject to change without notice...

Page 3: ......

Page 4: ...ess 18 Set Language Selection 18 Set Date and Time 19 Set Temperature Units 19 Set Decimal Resolution 19 Switching Modes Remote Control Standalone 19 4 6 Powering Off 19 4 7 Thermocouple Fixture 20 In...

Page 5: ...Contents Kaye HTR 420 User Manual 5 8 3 Troubleshooting 37 Appendix 38 9 1 Warranty 38 9 2 Return Policy 39 Customer Support Centers 40...

Page 6: ...be and RF ValProbe The firmware is backward compatible with all version of Kaye software without need for software upgrades This functionality allows the unit to be utilized for fully automatic calibr...

Page 7: ...g handle 3 Steel housing 4 Touch screen for display and operation 5 Calibrator exhaust ventilation 6 Connection for external reference probe 7 USB port for connection to Kaye hardware 8 Main switch wi...

Page 8: ...luded with a sleeve which can accommodate upwards of three 3 thermocouples The sleeves are optimized to handle 22AWG thermocouples which are similar others currently utilized in existing Kaye dry bloc...

Page 9: ...s the set points the stability criteria and deviation criteria The user simply starts the calibration from the Kaye software and the control of the calibration is automated No additional interaction w...

Page 10: ...ou may also call our European headquarters in Germany at 49 0 7231 14335 0 1 5 Calibration and Repair Information To schedule and send the HTR 420 to Kaye for calibration or repair 1 Contact the Kaye...

Page 11: ...Hazard Signs and Symbols below for list of symbols used in this manual and on the HTR 420 Table 1 Hazard Signs and Symbols Before you install the HTR 420 read through this user manual carefully If the...

Page 12: ...as otherwise the warranty is rendered null and void Special Safety Instructions CAUTION Risk of Burns The calibrator can become very hot when in operation Touching hot parts can result in serious bur...

Page 13: ...periods of non use moisture can seep into the heating elements magnesium oxide For drying the calibrator must be slowly heated up During this process the calibrator has not yet reached the required i...

Page 14: ...splay Unit Display Unit Brilliant Color 7 Touchscreen Viewing angle range 120 to 140 Brightness 400 cd m2 Unit C F K Resolution 0 1 0 01 0 001 C F K General Data Interface Serial to Validator Ethernet...

Page 15: ...ny damage Check the completeness of the delivery based on the packing slip and or purchase order The X0385 HTR 420 comes with the following components Item Description Quantity 1 HTR 420 1 2 6 ft 2 me...

Page 16: ...pace above the machine Sufficient ventilation must be ensured Do not operate near flammable materials The ventilation openings must not be blocked or covered The machine must be installed in a manner...

Page 17: ...Switch on the front panel Once powered on the Kaye HTR 420 splash screen appears for approximately thirty seconds followed briefly by the model and firmware version before presenting the Remote Contr...

Page 18: ...lt by tapping on the Display Settings calculator icon then choose Brightness on the Set Display window Enter the desired value 1 through 100 for screen brightness on the numeric keyboard Confirm selec...

Page 19: ...e the change and return you to the Calibrator Set Up window Switching Modes Remote Control Standalone To switch to Remote Control mode from the Standalone Main mode simply tap the Validator icon To sw...

Page 20: ...screws to hold the cover in place 1 Intergrated metal holder 2 HEX key 3 Thermocouple housing 4 Three housing screws 5 Cover 6 Three knurled head screws Installation Let the calibrator cool before in...

Page 21: ...afe temperature before touching or removing the holder Remove the IRTD and sensors and the three knurled knob screws Remove the cover Remove the thermocouples from the housing notches by rotate the me...

Page 22: ...lated offsets to the Kaye hardware Calibration Verification reports are generated by the applicable Kaye software See the appropriate Kaye Software manual for detailed instructions on how to setup the...

Page 23: ...he sensor can go no further without bending Note Due to the high heat capabilities of the HTR 420 Kaye recommends using Kapton wires over Teflon as Teflon can melt at temperatures over 220 C Connect t...

Page 24: ...set point red and the External Reference Probe value blue in digital and graphical format The graph displays the reference value RV in blue and target test point SP in red User can zoom in or out the...

Page 25: ...s ramp and soak profiles perform datalogging and report generation In Standalone mode utilizing the easy to use touchscreen the user has the flexibility of configuring these parameters under Test Task...

Page 26: ...with Kaye products Test Task Selection Using this parameter field you can reach the Select Test Task screen There you can select the saved test tasks and create or configure your own test tasks Power...

Page 27: ...essed and the relevant screen is displayed Copy The selected entry is copied and the relevant screen is displayed Create New A new entry is generated for the selection list and the relevant screen is...

Page 28: ...eens for changing set points function or alarm settings Configuration Range The operation of the calibrator via the configuration range is particularly well suited for one off testing processes You ca...

Page 29: ...protected test tasks cannot be deleted nor edited They serve as templates for your own self defined test tasks You can define your own test tasks for different test sequences These test tasks are dir...

Page 30: ...is adopted you are then returned to the previous window Functionality Here you can link the desired function of the calibrator with the test task IMPORTANT The selected function must be suitable for...

Page 31: ...Tap on the create icon for a new test point The window for the test point setting is opened Input the temperature the dwell time and gradient then confirm the relevant input When the input values are...

Page 32: ...r field Number of Steps to change the number of steps Input the desired number and confirm the input The number of steps is adopted the interval is calculated afresh Set Dwell Time Tap on the paramete...

Page 33: ...ther The instructions regarding the installation site and the operational position have been complied with The electrical connections have been made correctly The electrical connection has been ground...

Page 34: ...ars displaying current reference value RV in blue and target test point SP in red along with current elapsed time of test User can zoom in or out the graph by tapping on the plus or minus icons User c...

Page 35: ...To stop testing manually touch and slide the left arrow next to Stop all the way to the left To obtain logged data tap on the data icon to bring up the Select Log Data screen Tap on the desired file...

Page 36: ...y or slightly damp lint free cloth Do not use sharp objects or aggressive agents for cleaning Ensure that your cleaning agent cannot be a source of danger from a reaction with parts of the machine or...

Page 37: ...short circuit Contact Kaye for service Fan not running The fan is defective or blocked The temperature switch may have been triggered switching off power supply to the heart cartridge Contact Kaye for...

Page 38: ...the Kaye HTR 420 was defective the warranty period is One year for general electronics or mechanical failures If Amphenol Advanced Sensors determines that the HTR 420 was damaged by misuse improper i...

Page 39: ...anced Sensors instructs you to send the unit to a service center it must be shipped prepaid to the authorized repair center indicated in the shipping instructions 3 Upon receipt Amphenol Advanced Sens...

Page 40: ...Services Amphenol Advanced Sensors GmBH Sinsheimer Strasse 6 D 75179 Pforzheim Germany T 49 0 7231 14335 0 F 49 0 7212 391 035 E kaye amphenol sensors com Brazil Sales and Services Amphenol TFC DO Br...

Page 41: ...mphenol Corporation All Rights Reserved Specifications are subject to change without notice Other company names and product names used in this document are the registered trademarks or trademarks of t...

Reviews: