Table 13-7
Information requirements for heat pump space heaters and heat pump combination heaters
Model(s):
KEM-140 DRS5 KH
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
For low-temperature heat pumps, parameters shall be declared for low-temperature application. Otherwise,
parameters shall be declared for medium-temperature application. Parameters shall be declared for average
climate conditions.
Item
Rated heat output
(3)
at Tdesignh = -10
(-11) °C
Seasonal coefficient of performance
Symbol
Prated
=Pdesignh
SCOP
Power consumption in modes other than active mode
Supplementary heater (to be declared even if
not provided in the unit)
Outdoor heat exchanger
For air-to-water HP: Rated
air flow rate
For water-to-water: Rated
water flow rate
For brine-to-water: Rated
brine flow rate
Other items
T
j
= -7°C
T
j
= +2°C
T
j
= +7°C
T
j
= +12°C
T
j
= bivalent temperature
T
j
= operation limit temperature
For air-to-water heat pumps:
T
j
= – 15 °C (if TOL < – 20 °C)
Bivalent temperature (m2°C)
Cycling interval capacity for heating
at T
j
= -7°C
Degradation coefficient
(4)
at T= -7°C
Cycling interval capacity for heating
at T
j
=+2°C
Degradation coefficient
(4)
at T= +2°C
Cycling interval capacity for heating
at T
j
= +7°C
Degradation coefficient
(4)
at T
j
= +7°C
Cycling interval capacity for heating
at T
j
=+12°C
Degradation coefficient
(4)
at T
j
= +12°C
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Capacity control
Fixed/Variable Variable
Sound power level, indoors
Sound power level, outdoors
Contact details
(1) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to
the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to
the supplementary capacity for heating sup(Tj).
(2) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Rated heat output(3)
Type of energy input
P
OFF
P
TO
P
SB
P
CK
L
WA
L
WA
Name and address of the manufacturer or its authorised representative.
--
93
dB(A)
dB(A)
0.14
0.35
0.14
0
--
50000
--
--
Psup
= sup(Tj)
Q
airsource
Q
watersource
Q
brinesource
Pdh
Pdh
Pdh
Pdh
Pdh
Pdh
Pdh
Tbiv
Pcych
Cdh
Pcych
Cdh
Pcych
Cdh
Pcych
Cdh
84.31
51.47
33.65
39.85
84.31
83.15
--
-7
--
--
--
--
--
--
--
--
Active mode coef. of
performance
Net seasonal coef. of
performance
Item
Seasonal space heating
energy efficiency
Value
94
3.73
Unit
kW
--
kW
kW
kW
kW
kW
kW
kW
°C
kW
--
kW
--
kW
--
kW
--
T
j
= -7°C
T
j
= +2°C
T
j
= +7°C
T
j
= +12°C
T
j
= bivalent temperature
T
j
=operation limit temperature
For air-to-water heat pumps:
T
j
=–15°C (if TOL<–20°C)
For air-to-water HP :
Operation limit
temperature
(maximum-7°C)
Heating water
operating limit temperature
Cycling interval efficiency
at T
j
= +7°C
Cycling interval capacity for
heating at T
j
=+12°C
Cycling interval efficiency
at T
j
= +7°C
Cycling interval capacity for
heating at T
j
=+12°C
COPd
COPd
COPd
COPd
COPd
COPd
COPd
TOL
WTOL
COPcyc
COPcyc
COPcyc
COPcyc
2.38
3.46
5.34
7.14
2.38
2.11
--
-10
--
--
--
--
--
--
--
--
--
--
--
--
°C
°C
--
--
--
--
kW
kW
kW
kW
kW
m
3
/h
m
3
/h
m
3
/h
Symbol
η
s
SCOP
on
SCOP
net
Value
146
--
--
Unit
%
--
--
[yes]
[yes/no]
[yes/no]
[yes/no]
[yes/no]
[yes/no]
52