47
Table 13-5
Information requirements for heat pump space heaters and heat pump combination heaters
Model(s):
KEM-60 DRS4.1 KH
Air-to-water heat pump:
[yes]
Water-to-water heat pump:
[yes/no]
Brine-to-water heat pump:
[yes/no]
Low-temperature heat pump:
[yes/no]
Equipped with a supplementary heater:
[yes/no]
Heat pump combination heater:
[yes/no]
For low-temperature heat pumps, parameters shall be declared for low-temperature application. Otherwise,
parameters shall be declared for medium-temperature application. Parameters shall be declared for average
climate conditions.
Item
Symbol Value Unit
Item
Symbol Value Unit
Rated heat output
(3)
at Tdesignh = -10
(-11) °C
Prated
=Pdesignh 36.15 kW
Seasonal space heating
energy efficiency
η
s
145.89
%
Seasonal coefficient of performance
SCOP
3.72
--
Active mode coef. of
performance
SCOP
on
--
--
Net seasonal coef. of
performance
SCOP
net
--
--
T
j
= -7°C
Pdh
31.98 kW T
j
= -7°C
COPd
2.53
--
T
j
= +2°C
Pdh
20.24 kW T
j
= +2°C
COPd
3.59
--
T
j
= +7°C
Pdh
13.05 kW T
j
= +7°C
COPd
4.85
--
T
j
= +12°C
Pdh
14.21 kW T
j
= +12°C
COPd
5.67
--
T
j
= bivalent temperature
Pdh
31.98 kW T
j
= bivalent temperature
COPd
2.53
--
T
j
= operation limit temperature
Pdh
34.92 kW T
j
=operation limit temperature COPd
2.23
--
For air-to-water heat pumps:
Tj = – 15 °C (if TOL < – 20 °C)
Pdh
--
kW For air-to-water heat pumps:
T
j
=–15°C (if TOL<–20°C)
COPd
--
--
Bivalent temperature (m2°C)
Tbiv
-7
°C
For air-to-water HP :
Operation limit
temperature
(maximum-7°C)
TOL
-10
°C
Cycling interval capacity for heating
at T
j
= -7°C
Pcych
--
kW
Degradation coefficient
(4)
at T= -7°C
Cdh
--
--
Heating water
operating limit temperature
WTOL
--
°C
Cycling interval capacity for heating
at T
j
=+2°C
Pcych
--
kW
Cycling interval efficiency
at T
j
= +7°C
COPcyc
--
--
Degradation coefficient
(4)
at T= +2°C
Cdh
--
--
Cycling interval capacity for heating
at T
j
= +7°C
Pcych
--
kW Cycling interval capacity for
heating at T
j
=+12°C
COPcyc
--
--
Degradation coefficient
(4)
at T
j
= +7°C
Cdh
--
--
Cycling interval efficiency
at T
j
= +7°C
COPcyc
--
--
Cycling interval capacity for heating
at T
j
=+12°C
Pcych
--
kW Cycling interval capacity for
heating at T
j
=+12°C
COPcyc
--
--
Degradation coefficient
(4)
at T
j
= +12°C
Cdh
--
--
Supplementary heater (to be declared even if
not provided in the unit)
Power consumption in modes other than active mode
Off mode
P
OFF
0.030 kW
Rated heat output(3)
Psup
= sup(T
j
)
--
kW
Thermostat-off mode
P
TO
0.030 kW
Type of energy input
Standby mode
P
SB
0.030 kW
Outdoor heat exchanger
Crankcase heater mode
P
CK
0.000 kW For air-to-water HP: Rated air
flow rate
Q
airsource
24000 m
3
/h
Other items
For water-to-water: Rated
water flow rate
Q
watersource
--
m
3
/h
Capacity control
Fixed/Variable
Variable
Sound power level, indoors
L
WA
x
dB(A)
For brine-to-water: Rated
brine flow rate
Q
brinesource
--
m
3
/h
Sound power level, outdoors
L
WA
86
dB(A)
Contact details
Name and address of the manufacturer or its authorised representative.
(1) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to
the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the
supplementary capacity for heating sup(Tj).
(2) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Summary of Contents for KEM-90