background image

FP function

LOCK function

O

Keep pressing Fan button for more than 2 seconds to activate/disable Silence 
function(some units).

Due to low frequency operation of compressor, it may result in insufficient cooling 
and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while 
operating will cancel silence function.

Silence function

Clean

5s

5s

Boost

Press this button 2 times during one second under HEAT Mode and setting temperature of 

O

O

 

17  C/62  F or 20  C/(for models of 

KID- 05.1 S

 and  KID-05 S

).

The unit will operate at high fan speed (while
compressor on) with temperature automatically
set to 8 C/46 F.  

Note: 

This function is for heat pump air conditioner only. 

Press this button 2 times during one second under HEAT Mode and setting 
temperature of 17 C/62 F or 20 C(for models of 

KID- 05.1 S

 and  KID-05 S

) to activate 

FP function.Press On/Off, Sleep, Mode, Fan and Temp. button while operating will 
cancel this function.

2

+

Press together 

Clean

 button and 

Boost 

button at the 

same time more than 5 seconds to activate Lock function.

All buttons will not response except pressing these two 
buttons for two seconds again to disable locking.

2s

TURBO Function

Press TURBO button

Turbo

When you select Turbo feature in COOL mode, the unit will blow cool air

with strongest wind setting to jump-start the cooling process.

When you select Turbo feature in HEAT mode, for units with Electric heat

elements, the Electric HEATER will activate and  jump-start the heating

process.

10

Summary of Contents for KID-05.1 S KID-05 S

Page 1: ... you for purchasing our air conditioner Please read this manual carefully before operating your new air conditioning unit Make sure to save this manual for future reference USER MANUAL Remote Controller KID 05 1 S KID 05 S ...

Page 2: ...ble of Contents Remote Controller Specifications 02 Handling the Remote Controller 03 Buttons and Functions 04 How to Use Advanced Functions 09 Remote Screen Indicators 05 01 How to Use Basic Functions 06 ...

Page 3: ... effect When there are wide differentces between Remote controller Manual and USER S MANUAL on function description the description of USER S MANUAL shall prevail 02 Remote Controller Specifications Quick Start Guide 8m 3 0V Dry batteries R03 LR03 2 5 C 60 C 23 F 140 F FIT BATTERIES POINT REMOTE TOWARD UNIT PRESS POWER BUTTON SELECT MODE SELECT TEMPERATURE SELECT FAN SPEED 1 6 2 5 4 My Mod e Follo...

Page 4: ... the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide...

Page 5: ...ver auto swing feature Set timer to turn unit on or off NOTE HEAT mode is not supported by the cooling only appliance Used to start stop the Self Clean function Turns indoor unit s LED display and air conditioner buzzer on and off model dependent which create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in shortest possible time Selects fan speeds in ...

Page 6: ...rature Timer Fan speed display Active clean feature display Fresh feature display Sleep mode display Follow me feature display Wireless control feature display some units Low battery detection display If flashes Displays when LOCK feature is activated Silence LOW MED HIGH AUTO Lights up when remote sends signal to indoor unit Displays selected fan speed Displays the current including mode 2 20 21 ...

Page 7: ...matically select the COOL FAN or HEAT operation based on the set temperature 1 Press the MODE button to select AUTO 2 Set your desired temperature using the TEMP or TEMP button Set your desired temperature using the TEMP or TEMP button 3 Press the ON OFF button to start the unit Press the ON OFF button to start the unit NOTE FAN SPEED can t be set in AUTO mode COOL Mode Basic operation 1 Press the...

Page 8: ...utton to start the unit 1 Press the MODE button to select HEAT mode 2 3 Press FAN button to select the fan speed AUTO LOW MED or HIGH 4 DRY Mode dehumidifying NOTE FAN SPEED cannot be changed in DRY mode HEAT Mode NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such instances we recommend using this air conditioner in conjunction with other heating...

Page 9: ...24 2 Cancel either function by setting its timer to 0 0h Point remote to unit and wait 1sec the TIMER ON will be activated Press TIMER button to initiate the OFF time sequence Point remote to unit and wait 1sec the TIMER OFF will be activated Current time 1PM 2 00PM 3 00PM 4PM 5PM 6PM Timer starts Unit turns ON Unit turns OFF 2 5 hours later 5 hours later 3 30PM Example If current timer is 1 00PM ...

Page 10: ...clean itself automatically After cleaning the unit will turn off automatically Pressing the CLEAN button mid cycle will cancel the operation and turn off the unit You can use CLEAN as often as you like Note You can only activate this function in COOL or DRY mode Swing LED Clean SHORTCUT function Press SHORTCUT button Push this button when remote controller is on the system will automatically rever...

Page 11: ... for heat pump air conditioner only Press this button 2 times during one second under HEAT Mode and setting temperature of 17 C 62 F or 20 C for models of KID 05 1 S and KID 05 S to activate FP function Press On Off Sleep Mode Fan and Temp button while operating will cancel this function 2 Press together Clean button and Boost button at the same time more than 5 seconds to activate Lock function A...

Page 12: ...conditioner to optimize the temperature around you and ensure maximum comfort The SLEEP function is used to decrease energy use while you sleep and don t need the same temperature settings to stay comfortable This function can only be activated via remote control Note The SLEEP function is not available in FAN or DRY mode For the detail see sleep operation in USER S MANUAL When the FRESH function ...

Page 13: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CR275 RG10 D 16117000A37344 2020 07 31 ...

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: