Specifications
Page 24
9. Capacity Correction Factor for Height Difference
Capacity (Btu/h)
12K
Pipe Length (m)
Cooling
5
10
20
25
Height difference
H (m)
Indoor Upper
than Outdoor
10
0.973
0.948
0.936
5
0.995
0.983
0.958
0.945
0
1.000
0.988
0.963
0.950
Outdoor Upper
than Indoor
-5
1.000
0.988
0.963
0.950
-10
0.988
0.963
0.950
Heating
5
10
20
25
Height
difference
H (m)
Indoor Upper
than Outdoor
10
0.993
0.978
0.970
5
1.000
0.993
0.978
0.970
0
1.000
0.993
0.978
0.970
Outdoor Upper
than Indoor
-5
0.992
0.985
0.970
0.962
-10
0.977
0.962
0.955
Capacity (Btu/h)
18K
Pipe Length (m)
Cooling
5
10
20
30
Height difference
H (m)
Indoor Upper
than Outdoor
20
0.928
0.912
10
0.969
0.937
0.921
5
0.995
0.979
0.946
0.930
0
1.000
0.984
0.951
0.935
Outdoor Upper
than Indoor
-5
1.000
0.984
0.951
0.935
-10
0.984
0.951
0.935
-20
0.951
0.935
Heating
5
10
20
30
Height difference
H (m)
Indoor Upper
than Outdoor
20
0.982
0.976
10
0.994
0.982
0.976
5
1.000
0.994
0.982
0.976
0
1.000
0.994
0.982
0.976
Outdoor Upper
than Indoor
-5
0.992
0.986
0.974
0.968
-10
0.978
0.966
0.960
-20
0.959
0.953
Summary of Contents for KSDA-35 DVR14
Page 7: ...Specifications Page 7 3 Dimensional Drawings 3 1 Indoor Unit...
Page 8: ...Specifications Page 8 3 2 Outdoor Unit KUE 35 DVR13...
Page 9: ...Specifications Page 9 KUE 52 DVR13...
Page 10: ...Specifications Page 10 4 Centre of Gravity KUE 35 DVR13 KUE 52 DVR13...
Page 14: ...Specifications Page 14 KUE 35 DVR13 KUE 52 DVR13...
Page 49: ......