Specifications
Page 6
Outdoor coil
Number of rows
1
2.0
Tube pitch(a)x row pitch(b)
mm
21x22
21x22
Fin spacing
mm
1.3
1.3
Fin type (code)
Hydrophilic aluminum
Hydrophilic aluminum
Tube outside dia.and type
mm
ɸ
7,Inner groove tube
ɸ
7,Inner groove tube
Coil length x height x width
mm
745*504*22
860*504*44
Number of circuits
2
4
Outdoor air flow
m3/h
2200
2100
Outdoor sound pressure level
dB(A)
54
55
Outdoor sound power level
dB(A)
62
63
Throttle type
EXV
EXV
Outdoor unit
Dimension(W*D*H)
mm
765x303x555
805x330x554
Packing (W*D*H)
mm
887x337x610
915x370x615
Net/Gross weight
Kg
26.6/29
32.5/35.2
Refrigerant type
Type
-
R32
R32
GWP
-
675
675
Charged quantity
Kg
0.71
1.15
Design pressure
MPa
4.3/1.7
4.3/1.7
Refrigerant piping
Liquid side/ Gas side
mm(inch)
ɸ
6.35/
ɸ
9.52(1/4”/3/8”)
ɸ
6.35/
ɸ
12.7(1/4”/1/2”)
Max. refrigerant pipe length
m
25
30
Max. difference in level
m
10
20
Ambient temperature
Cooling
°C
-15~50
-15~50
Heating
°C
-15~24
-15~24
Qty’per 20’ /40’ /40’HQ
Outdoor unit
132/264/352
114/234/312
Notes:
1) Capacities are based on the following conditions:
Cooling(T1): - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
-Interconnecting Piping Length 5m - Interconnecting Piping Length 5 m
- Level Difference of Zero. - Level Difference of Zero.
2) Capacities are Net Capacities.
3) Due to our policy of innovation some specifications may be changed without notification.
Summary of Contents for KSDA-35 DVR14
Page 7: ...Specifications Page 7 3 Dimensional Drawings 3 1 Indoor Unit...
Page 8: ...Specifications Page 8 3 2 Outdoor Unit KUE 35 DVR13...
Page 9: ...Specifications Page 9 KUE 52 DVR13...
Page 10: ...Specifications Page 10 4 Centre of Gravity KUE 35 DVR13 KUE 52 DVR13...
Page 14: ...Specifications Page 14 KUE 35 DVR13 KUE 52 DVR13...
Page 49: ......