Care and Cleaning

CAUTION: ALWAYS TURN OFF THE POWER SWITCH AND DISCONNECT
THE POWER CORD FROM THE ELECTRICAL OUTLET BEFORE CLEANING.

Daily Maintenance:

1.

Lift the Water Tank from Base and empty all water from the Reservoir. Remove the Tank Cap
and drain any water from the Water Tank. Wipe it clean with a soft, damp cloth. The Mist
Nozzle should be removed during cleaning to prevent damage.

2.

Do not

immerse the Base in water. Gently wipe the Reservoir with a soft, clean, wet cloth.

Do not

attempt to remove or in any other way modify the Water Sensor. 

Use care

when

wiping around the Water Sensor; it is delicate and can be easily damaged. Rinse the Water
Tank with lukewarm water after each use. For storage, wipe dry with a soft, clean cloth. Keep
water away from the Air Outlet.

3.

Do not

use detergent to clean any water-containing parts of the humidifier. Detergents and

the film they leave behind can affect the output of the humidifier. 

Do not

use abrasive

cleansers or brushes.

4.

Do not

leave water in the Water Tank or Reservoir when unit is not in use as it may result

in the build up of mineral deposits and bacteria that can inhibit the output efficiency of the
humidifier. Please note that if water remains in the Water Tank for more than a day or two,
bacterial growth is possible.

Weekly Maintenance:

1.

Thoroughly clean humidifier every week using a solution of bleach and water (one teaspoon
of bleach in one gallon of water). Fill tank partially with this solution, let stand twenty (20)
minutes, shaking vigorously every few minutes, drain and rinse with clean water until the
bleach smell is gone. 

Do not

use detergents as they will interfere with performance of the

humidifier.

2.

Wipe the Reservoir with a soft cloth dampened in the solution. Rinse area thoroughly before
proceeding.

3.

If mineral deposits are evident around the Nebulizer and Water sensor, clean their surfaces
with a soft, clean cloth and a small amount of undiluted white vinegar. If necessary for
removal of mineral deposits, mix a solution of 50% white vinegar and 50% water and fill
the base with enough solution to cover the Nebulizer. 

Do not

use detergents. 

Do not

immerse the Base in water. Allow it to soak for an hour. Then use a cotton swab to gently
loosen build up on the Nebulizer. Rinse out the Reservoir and wipe clean. 

Do not touch

Nebulizer with bare fingers

as any fingerprints or other residue can affect mist output.

Be careful not to damage the Water Sensor.

4.

All surfaces should be thoroughly cleaned with water prior to reuse. The Tank Cap can be
soaked in a solution of 50% white vinegar and 50% water if necessary to remove deposits.

End of Season Maintenance

1.

Follow above weekly cleaning procedure at the end of the humidification season, or when
the humidifier will not be used for several days, being sure to dry all parts. Allow the Water
Tank to air dry before storing. 

Do not

store with water inside.

2.

Leave Tank Cap partially loosened during storage to prevent Tank Cap and Gasket from
sticking together. This will prolong the life of the gasket.

3.

Clean the Tank and Base after long periods of storage.

Troubleshooting Guide

If your Humidifier is not working properly, refer to the following:

Problem

Power Switch is set to “On” and
Power Indicator is off

Little or no mist is produced

Water overflows from Reservoir

Condensation forms around humid-
ifier or windows

White Dust Accumulation

Possible Cause

• Unit not plugged in
• No power at outlet

• No water in tank
• Unit is not level
• Mineral deposits on Nebulizer or

Water Sensor

• Water Tank was washed with

detergent

• Blower not operating

• Water is too cold.
• Blower operating but mist not

exiting through mist nozzle

• Nebulizer not functioning

• Tank may be leaking

• Tank Cap is not tight
• Nebulizer is not working properly

• Mist Intensity is set too high 

for room size or preexisting
humidity level.

• Hard water used

Solution

• Plug unit in
• Check circuits, fuses, test outlet.

• Fill Water Tank.
• Place on a level surface.
• Clean Nebulizer and Water

Sensor per instructions.

• Rinse thoroughly with clean

water.

• Ensure water in base is adequate

to immerse Water Sensor.

• Use room temperature water.
• Reservoir overfilled. Empty

Reservoir and replace tank.

• Clean Nebulizer per instructions.

• Check the Tank for leaks and

replace if necessary

• Tighten Tank Cap
• Clean Nebulizer per instructions.

• Decrease mist output to low 

(on 2-speed models) or open
door to the room.

• Use distilled water

Note:

Failure to keep this unit clean from mineral deposits normally contained in any water sup-

ply will affect the efficiency of operation of this unit. Customer failure to follow these instructions
may void the warranty.

Summary of Contents for 5520B

Page 1: ...ief from dry indoor air Quiet Ultrasonic technology produces cool superfine mist Whisper Quiet If you have any questions about the operation of your ultrasonic humidifier call our toll free Consumer Service line at 800 477 0457 k Manufacturing Quality Healthcare Products for Over 75 Years Model 5520B 5522G 5524P ...

Page 2: ...n the unit 8 Do not immerse the base in water or other liquid Do not overfill 9 Humidifier should always be unplugged and emptied when not in operation or while being cleaned Shut off and unplug humidifier before moving Do not move or tilt humidifier while it is operating Plug and unplug unit with dry hands 10 The humidifier should not be left unattended in a closed room since air could become sat...

Page 3: ...install the Mist Nozzle on the Water Tank Operating Instructions 1 Do not operate the humidifier without water in the Water Tank 2 After filling the humidifier be sure the Power Switch is in the OFF position then plug the power cord into a 120 volt AC wall outlet 3 Turn the Switch to either the Hi or Low position The Power Indicator will illuminate 4 Mist will not appear immediately Allow a few mi...

Page 4: ...on swab to gently loosen build up on the Nebulizer Rinse out the Reservoir and wipe clean Do not touch Nebulizer with bare fingers as any fingerprints or other residue can affect mist output Be careful not to damage the Water Sensor 4 All surfaces should be thoroughly cleaned with water prior to reuse The Tank Cap can be soaked in a solution of 50 white vinegar and 50 water if necessary to remove ...

Page 5: ...uding the entire appliance will be at the discre tion of Kaz Incorporated repaired or replaced at no charge if the appliance has not been tampered with and has been used according to these printed directions Retain receipt to prove warranty This Warranty gives you specific legal rights as well as other rights that vary from state to state If you experience unsatisfactory operation first refer to t...

Reviews: