VENTILATION FAN

WARNING

Models:  SNP100            SNP100H

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

manufacturer at the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means 

cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all 

applicable codes and standards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of 

fuel burning  equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire Protection Association (NFPA), and 

the American Society for Heating, Refrigeration and Air Conditioning  Engineers (ASHRAE), and the 

local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - 

protected branch circuit (ceiling installation only).

8. This unit must be grounded.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4. Please read specification label on product for further information and requirements. 

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attach-

ment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the 

exact service motor. The impeller should also be replaced.

See “CONNECT ELECTRICAL WIRING” for details.

For SNP100H the humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid increases in humidity or (b) humidity above a 

user-adjustable set-point (30%-80% relative humidity). The humidity sensor may occasionally turn the fan ON when environmental conditions change. If 

the fan continuously responds to changing environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for 

about 80% (Ambient temperature of 25

)

.

SENSITIVITY

 

ADJUSTMENT

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H” may need 

to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, movement toward less “-” “H” may be 

required.

To adjust the “H”:

1. Disconnect power at service entrance.

2. Through the grille, locate the slot marked “H”.

3. Carefully rotate the “H” adjustment toward “+” or “-”.

4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.

5. Repeat above steps if necessary.

When the temperature changes, humidity sensor values will have deviation.

Cod: 0060302843-B