14
CAUTION
This unit is designed for countertop
installation only.
DANGER
It is required that you connect this unit only
to a GFCI protected receptacle. It is strongly
recommended that you do not use an adapter
or an extension cord to connect this unit
because of potential safety hazards.
Clearance
Electrical Requirements
• Do not block the air vent on left side.
• Allow for minimum 12 inches of clearance on
the left side.
• Allow for minimum 1/2 inch of clearance on the
right side.
• Allow for minimum 2 inches of clearance on
the back.
• Allow for minimum 1/2 inch of clearance on
the top.
• A dedicated 120V, 60Hz, 15A fused, grounded
electrical supply is required. We recommended
a separate circuit serving only your appliance.
• We do not recommend using outlets that can
be turned off by a switch.
• Only plug the unit into a grounded 3 prong
outlet.
INSTALLATION
INSTRUCTIONS
Location
• Place the unit away from direct sunlight and
heat sources.
• Do not install the unit in moist areas.
• Do not install the unit in garage.
• Do not install the unit where the ambient
temperature range will be below 50 °F or
above 90 °F. Otherwise, the unit will not be
able to work properly.
• The unit must be placed in a properly
ventilated location to prevent heat build-up
generated by the refrigeration system. Failure
to do so will prevent the unit from cooling
properly, and may result in damage to unit
components as well as its contents.
• The unit must be installed on a counter that is
level and strong enough to support up to 50 lb.
CAUTION
This unit is designed for indoor use only.