background image

 

Thrulink Operations Manual 

 

PREFACE 

 
 
PART NUMBER CONFIGURATOR 

 

THLK - 

…

 

…

 - 

…

 X 

 

THLK Product 

Series 

 

…

 

Throughput Capacity Indicator (S= Standard; H= High) 

 

…

 

Number of Ethernet Ports (2= 1 LAN and 1 WAN; 3= 2 LAN and 1 WAN) 

 

…

 

Chassis style (W= wall mount; R= rack mount) 

 

Power Supply plug type (A= US; B= UK; C= Europe) 

 

KBC THRULINK PART NUMBERS  
This operations manual covers the following part numbers: 

 

DESCRIPTION 

     KBC 

PART 

NUMBER 

Standard Capacity unit with 1 LAN port: 

 

 

THLK-S2-Wx 

Standard Capacity unit with 2 LAN ports: 

 

 

THLK-S3-Wx 

High 

Capacity 

server 

unit: 

    THLK-H2-Rx 

Note: Standard capacity only available in wall mount, high capacity only available in rack mount. 

 

Accessories: 

 

1000 mA 12 VDC non-regulated power supply* 

 

PS-1000-x 

 

* One included in THLK-S series kits, not used for THLK-H series 

 

PRODUCTS INCLUDED IN KITS 
 
THLK-S series 
Qty 1:  ThruLink Standard Capacity unit with appropriate number of LAN ports 
(according to selected part number) 
Qty 1:  1000 mA power supply with appropriate plug 
Qty 1:  Operations manual 
Note: a manual may only be included in one box if multiple units are ordered 
 
THLK-H series 
Qty 1:  ThruLink High Capacity server. 

Unit must be in environmentally conditioned location

 

Qty 1:  Power cord with appropriate plug 
Qty 1:  Operations manual 
Note: a manual may only be included in one box if multiple units are ordered 
 
 

 

 

 

 

 

 
 

 

Thrulink Operations Manual 

 

PREFACE (CONTINUED) 

 
TECHNICAL SUPPORT AVAILABILITY 
This manual is comprehensive to the extent that it will answer many of your technical 
questions. Our toll free technical assistance is available should you require additional 
assistance. KBC offers technical support over the phone or by way of e-mail to all KBC 
qualified integrators on the ThruLink product. The North American technical support 
hotline is available during regular US west coast business hours, Monday through Friday 
on all non-major holiday business days. KBC will follow up on all electronic inquiries 
before the end of the following business day. See below for global tech support. 
 
NORTH AMERICA  
888-366-4276: Monday – Friday 10am-8pm Eastern (7am-5pm Pacific) 

techsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
HAWAII & ALASKA / GUAM, PR & OTHER US TERRITORIES 
949-297-4930: Monday – Friday 7am-5pm Pacific Time 

techsupport@kbcnetworks.com

: 24hr availability, response time varies 

Note: the toll free 800# does not work from Alaska 
 
CENTRAL / SOUTH AMERICA 

techsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
ASIA 

apactechsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
SOUTH PACIFIC / PACIFIC ISLANDS 

apactechsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
EUROPE 
+44(0)1622 418782: Monday – Friday 9am-5pm UK Time 

emeatechsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
MIDDLE EAST 

emeatechsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
AFRICA 

emeatechsupport@kbcnetworks.com

: 24hr availability, response time varies 

 
Technical Support is offered in English, however, KBC has worldwide representatives 
who can provide technical support in many local languages. 
 
Please note: technical assistance is available after having read through this manual. 
Comprehension of terms and topics will assist in trouble-shoot procedures. 
 

 

 

 

 

 

 
 
ii 

Summary of Contents for ThruLink THLK Series

Page 1: ... A Main 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com ThruLink LAN WAN Transmission Systems Operations Manual Version 20110519 ...

Page 2: ...hnical assistance is available should you require additional assistance KBC offers technical support over the phone or by way of e mail to all KBC qualified integrators on the ThruLink product The North American technical support hotline is available during regular US west coast business hours Monday through Friday on all non major holiday business days KBC will follow up on all electronic inquiri...

Page 3: ...IGH CAPACITY ENVIRONMENTAL CONDITIONING The High Capacity ThruLink is an industrial server and must be stored in a conditioned environment Maintain temperature ratings in the server room within the temperature threshold as stated on the device specifications and ratings Rack Mount Instructions The following or similar rack mount instructions are included with the installation instructions A Elevat...

Page 4: ...f cable is usually determined by the laptop Ethernet port If using a 10 100 port a crossover cable may be required If using a gigabit port the straight through cable should connect to the ThruLink 3 Connect the supplied 12 VDC 1000mA power supply to the DC jack as labeled on the Standard Capacity SC Connect the power supply to a sufficient voltage suppression device 4 Configure the static setting ...

Page 5: ...pair can be sent directly to KBC with a valid RA number RA s are issued to KBC distributors dealers or integrators with a valid resale license End users should return products through their KBC dealer who can call or e mail KBC to obtain an RA number for repair 3 Thrulink Operations Manual THRULINK PHYSICAL DETAILS STANDARD CAPACITY STANDARD CAPACITY SINGLE DUAL LAN PORT THLK S2 Wx THLK S3 Wx A RE...

Page 6: ...t both types of cables are on hand in case your particular device requires a different configuration than what KBC has tested 6 A REAR VIEW 1 Fan 2 Power Input Port 3 Serial Connection 4 WAN port 5 LAN port B FRONT VIEW 6 LCD Display 7 Power Off Hold for two seconds 8 Power On Hold for two seconds 12 VDC PS Ethernet Cat5 or 6 cable connect to network Ethernet Cat5 or 6 cable To PC serial port for ...

Page 7: ...INK TUNNEL Out of the box the ThruLink units are set to default Tunnel Mode Disabled In order to connect two or more units together one unit must be enabled as SERVER and the other s to which the Server will connect must be configured as CLIENT S Each Client must have its respective Server WAN IP entered into the Primary Server IP section The WAN Configuration above shows the IP and netmask chosen...

Page 8: ...able IP on the same subnet as the Server other than the Server LAN IP 17 Click SAVE and then reboot device Visit www thrulink net TLV2 to view a brief web tutorial for 2 minute KBC ThruLink tunnel set up procedure 9 Thrulink Operations Manual ADVANCED OPERATION WEB BROWSER INTERFACE Each ThruLink has a web browser interface to access the advanced setup functions If changing advanced settings be su...

Page 9: ...ommand tool to be used along with the Command Prompt to ping trace the LAN or WAN IP addresses of other ThruLink or Ethernet devices on the network 11 Thrulink Operations Manual ADVANCED OPERATION CONTINUED Network Diagnostics Continued SNMP Enable Default configuration is SNMPv3 Disabled To enable simply click the Blue Disabled button in order to see the Enabled option 3 System The opening page o...

Page 10: ...hing link STATUS ACTIVE Upon a link to Server WAN IP STATUS LINK LOST If the Client loses the link it will reattempt the connection STATUS INCORRECT SERVER WAN IP STATUS UNABLE CONTACT If the Server WAN IP is correct check the port selected to ensure ports are forwarded STATUS PSK MISMATCH 13 Thrulink Operations Manual ADVANCED OPERATION CONTINUED c WAN Interface Media Type IEEE 802 11 Wireless Et...

Page 11: ...llow access through only the LAN or only the WAN port s ii Tunnel Mode Options The ThruLink is set to Disabled Tunnel mode out of the box The user must select the intended mode for each ThruLink device KBC recommends setting the Server first as the Client must have the Server WAN IP information entered into it to connect the tunnel The various options are shown below 1 Server Mode Below are the op...

Page 12: ... In the picture below the Client is set to communicate to its primary Server whose WAN IP address is 10 0 0 10 on Port 8080 The Host Name does not need to match the Server Host Name in order to establish the tunnel A secondary Server if one is available can be used as the Failover Server in the event the connection is lost to the primary Server A failover Server will only receive the information f...

Page 13: ...ng Below are the options to select the DNS settings 2 Example of settings The following are example configurations insert your settings from your ISP 19 Thrulink Operations Manual ADVANCED OPERATION CONTINUED a LAN Configuration Select a LAN IP and Subnet mask See page 9 if the LAN configuration will match the existing network settings If a different subnet will be used select the desired configur...

Page 14: ...GUI interface cannot be reached via the LAN or WAN ports set up can be performed through the serial connection The console is designed to change only the minimum required information to enable access to the system via a network Once network access has been established the web GUI provides complete system configuration as detailed in pages 8 through 21 To use the serial console of the system a null...

Page 15: ... plug type determined by part number APPROVALS FCC ID IC CE Warranty 2 YEAR LIMITED WARRANTY SEE PAGE 25 FOR DETAILS 23 Thrulink Operations Manual THRULINK PRODUCT SPECIFICATIONS CONTINUED For product improvement design and specifications are subject to change without notice HIGH CAPACITY THLK H2 Rx Series Bandwidth 650 Mbps unencrypted 400 Mbps encrypted 128 bit NETWORK MANAGEMENT User Interface ...

Page 16: ... years from the date of initial sale for all fiber products 1 If within the specified warranty period this product or any part or portion thereof shall prove upon examination by KBC to be defective in material or workmanship KBC will repair or replace such part or portion at KBC s option The warranty period on the repaired or replaced part or portion of this product shall be limited to the unexpir...

Reviews: