INSTALLATIONS
Location Requirements
CAUTION
This unit is designed for indoor use only.
x
Place the unit away from direct sunlight and heat sources.
x
Do not install the unit in moist areas.
x
Do not install the unit in garage.
x
Do not install the unit where the ambient temperature range will be
below 50 °F or above 90 °F. Otherwise, the unit will not be able to work
properly.
x
The unit must be placed in a properly ventilated location to prevent heat
build-up generated by the refrigeration system. Failure to do so will
prevent the unit from cooling properly, and may result in damage to unit
components as well as its contents.
x
The unit must be installed on a counter that is level and strong enough
to support up to 50 lb.
Clearance Requirements
CAUTION
This unit is designed for countertop installation only.
x
Never block the air vent on the left side.
x
Allow for minimum 4 inches of clearance on both left and right sides.
x
Allow for minimum 3 inches of clearance on the back.
x
Allow for minimum 1/2 inch of clearance on the top.
Electrical Requirements
DANGER
It is required that you connect this unit only to a GFCI protected
receptacle. It is strongly recommended that you do not use an
adapter or an extension cord to connect this unit because of
potential safety hazards.
x
A dedicated 120V, 60Hz, 15A fused, grounded electrical supply is
required. It is recommended that a separate circuit serving only your
appliance be provided.
x
Only connect to properly polarized outlets.
x
Use outlets that cannot be turned off by a switch.
x
Only plug the unit into a grounded 3 prong outlet.