21
2
2
Operation and Service KBL 6900 / MAX10
5.3 Filter panes
Safety function
The facial tanners are equipped with an additional safety
function. Behind each of the filter panes there is a safety switch
that switches off the burner in the case of a missing or broken
pane.
Do not operate the tanning system with a defective filter pane.
Carry out regular visual inspections!
Filter panes have to be replaced only by those of the same type!
The filter panes may be dismantled and replaced by trained
expert staff only.
Filter panes in the
canopy or lateral
part
After dismantling the filter panes (see below), clean them with a
standard cleaning agent for glass and a soft cloth or chamois.
Illustr. 5-7 Remove filter pane cover
Illustr. 5-8 Remove pane from the
clamping springs
Mark
The filters are marked with
„KBL 3020 0191“
1
3
1
3
5
6
Step
Procedure
Reference
1
Dismantle the acrylic pane of the canopy or of the lateral
part.
see 5.2
2
Undo the screws of the filter pane cover (1), swing it out (2)
and pull it out (3).
Illustr. 5-7
3
Carefully and with both hands, press the filter pane down (4)
until the upper springs release the pane (5). Take the pane
out from above (6).
Illustr. 5-8
4
After cleaning the pane, mount it again in reverse order.