5.4 Tubes, facial and shoulder tanners
Dismantling
Carry out the following procedure to clean or replace tubes or
face and shoulder tanners:
Cleaning intervals
Coloured filter
To make sure that the tanning effect is maintained, we
recommend you to clean the tubes and UV radiators with warm
water and a chamois after approx. every 200 hours of use. Do
not use any aggressive or alcoholic cleaning agents.
The coloured filter (Sec. 5.7 Unit lighting) has to be replaced at
the latest when replacing the tanning tubes.
Replacement
intervals
Only replace tubes, face tanners, shoulder tanners and starters
with those of the same type!
When installing the tubes, make sure that the inscription is
visible, i.e. the reflector must be at the back.
For units equipped with CPI technology, it is essential to carry
out a reset after each tube replacement! (see Section 8.2.2)
For units equipped with inductive technology also install new
starters when replacing the tubes!
After each change of tubes, do not forget to reset the counter of
the service hours of the tubes. (see Section 8.3.)
Step
Procedure
Reference
1
Dismantle the canopy pane, base pane and lateral pane. Section 5.2
2
Remove the tube covers in the facial area.
Section 3.3.
3
For XXL-apparatuses: Release the tube covers at the
foot of the bed, which will give you free access to the
tubes.
4
For apparatuses equipped with burners: You will have to
dismantle the filter panes as well, if you want to replace
the burner.
Section 5.3,
5.5
5
Remove the covers of the shoulder tanner.
Section 5.6
All
tanning
units
All units
with
burners
Inductive
units
CPI units
Shoulder
tanner
Burner
Tubes
and
Starters
with facial
tanner mode
without facial
tanner mode
Eco
Power
Eco
Power Super P.
500
hrs.
500-600
hrs.
500-600
hrs.
1200
hrs.
1000
hrs.
1200
hrs.
1000
hrs.
800
hrs.
Carry out a reset!