background image

23

Operation and Service KBL 6900 / MAX10

Replacing tubes 
and starters in 
inductive units 

For units with inductive control, please note: 
The starter of the upper tube (#21) in the lateral part is located 
behind the decorative light tube on the left hand side (foot area). 

Illustr. 5-9 Starter of tube 21

Illustr. 5-10 Left socket for tube 21

Illustr. 5-11 Back of lateral reflector with starter of tube 21

Summary of Contents for 6900 MAX10

Page 1: ...Operating Instructions KBL 6900 MAX10...

Page 2: ...umentation covers only products manufactured by KBL AG This documentation must not be duplicated photocopied translated or stored on any electronic medium or in a machine readable form neither in whol...

Page 3: ...e pump 34 5 13 Changing aroma box aquaCool canister 34 5 14 Music system with MP3 player 35 5 15 Replacing the aquaCool nozzles 36 6 Technical data 37 6 1 Data which all apparatuses have in common 37...

Page 4: ...5 3 Do not operate the shoulder tanner without lamp unit Attention High light intensity do not look into the radiators Technical Parameters The data indicated in the tanning schemes are based on the...

Page 5: ...dards for sunlamp products under No 21 CFR 1040 20 This appliance is intended to be used with the following lamps Canopy megaLine 1856 R 200W HP Bench megaLine 1855 R 160W HP Facial units megaLine HP...

Page 6: ...yewear whenever equipment is energized Read the instruction booklet before using Follow the exposure schedule in accordance with your skin type Failure to do so may result in overexposure However rega...

Page 7: ...unters 8 2 2 Reset counter of service hours Check and grease ropes of the canopy drive 5 8 Check all inner tubes and if necessary change them Climatic apparatus Clean heat exchanger Check the function...

Page 8: ...S Shoulder tanner activeColor O Colour stimulation in red green or blue AquaCool O Misty water for refreshment Aroma and cabinBreeze O Fragrances in the sunbed and in the cabin AirCon O Air conditioni...

Page 9: ...sed the tanning lamps are turned on automatically If the touch key Start is pressed during this warm up time the lamps turn on immediately The facial tanners are always turned on only after a certain...

Page 10: ...touch key to switch on the apparatus during the warm up time If the tanning session has been interrupted by means of the Stop key it can be continued after touching the Start key once again provided...

Page 11: ...by pressing the or keys above the double arrow symbol The following menus are available which will be explained in more detail below Music channel Air Condition Colour stimulation Aroma Acoustic user...

Page 12: ...n or you can increase their output When the system has been switched off there will be a time lag before you can switch it on again due to the necessary cooling of the burners Here you can activate th...

Page 13: ...MP3 unit can only be controlled by one audio source i e either by the chip of the MP3 player or by an external music source Body fan The power of the body fan can be increased or reduced by steps of...

Page 14: ...case that the system has been switched off by means of the coin controlled system it can be switched on again immediately Colour stimulation The colour of the colour stimulation can be selected by mea...

Page 15: ...e available and configured The new music source is selected and displayed for a short time using the or keys above beneath the P For more information see service menu I The symbol channel selection me...

Page 16: ...ined with a gel Please note that the gel is not completely used up but a small rest will remain This sta tus is shown on the display so that the operator knows when to change the gel The fragrance com...

Page 17: ...orative may be switched on or off if the timer signal is not active by pressing the key sequence of the body fan You have to press the individual buttons within a period of 1 sec Please also bear in m...

Page 18: ...by chemically active agents such as inappropriate cleaning agents To clean the varnished and plastic surfaces use a damp soapy cloth It must be avoided at any rate that cleaning uid runs into the appa...

Page 19: ...derside of the base pane and the inner base section use a slightly damp micro bre cloth only You can also use it to clean the shoulder tanner You can use megaClean as a detergent spray the cloth with...

Page 20: ...e Illustr 5 4 3 Lift the base pane and x it to the canopy by means of the enclosed hooks Illustr 5 5 4 Clean the lower part of the base pane 5 If there is a duct pane in the bed you can take it out fo...

Page 21: ...nly Filter panes in the canopy or lateral part After dismantling the lter panes see below clean them with a standard cleaning agent for glass and a soft cloth or chamois Illustr 5 7 Remove lter pane c...

Page 22: ...al to carry out a reset after each tube replacement see Section 8 2 2 For units equipped with inductive technology also install new starters when replacing the tubes After each change of tubes do not...

Page 23: ...s with inductive control please note The starter of the upper tube 21 in the lateral part is located behind the decorative light tube on the left hand side foot area Illustr 5 9 Starter of tube 21 Ill...

Page 24: ...ing the burners please make sure that the contact surfaces of both sockets and burners are clean Insert the burners in a straight position into their sockets After being inserted into the socket the l...

Page 25: ...of the clamp downwards then take the new burner and place it into its exact position by paying attention to the recess in the socket After that press the socket downwards on the opposite side until it...

Page 26: ...nscrew the reflector Illustr 5 6 3 Disconnect the reflec tors at the respective ignition unit from the electrical system Illustr 5 6 5 Spread the clamp and take off the burner including socket Illustr...

Page 27: ...clean or replace it if necessary Illustr 5 14 Unit lighting in the lower front section and the starter for this tube on the left side Step Procedure Reference 1 Canopy Open the canopy pane and tilt i...

Page 28: ...e lid upper side 3 pcs The maintenance lid flaps forward together with a part of the reflector plate 5 The maintenance lid is hung up in hooks In order to remove the maintenance lid first press the lo...

Page 29: ...s well to see if they are dirty Section 5 10 Dirty heat exchangers considerably reduce the capacity of the air conditioning unit Vacuum clean the heat exchangers if necessary Filter mat in the canopy...

Page 30: ...ou will need a ratchet spanner with a 0 39 socket Illustr 5 18 Left tension screw Illustr 5 19 Right tension screw Step Procedure Reference 1 Check the ropes for wear If individual wires of the rope a...

Page 31: ...speed by hand this automatism is switched off Principle of the cooling system The following pictures illustrate the cooling system of the sunbed Ambient air if there is no air conditioning or cooled...

Page 32: ...In apparatuses with an air conditioning unit optional both base pane and canopy are cooled Ambient air is drawn in through the lter cooled in the air conditioning unit and led through an air hose to...

Page 33: ...the front cover and vacuum clean the heat exchangers if necessary Check the connection hose each time the tubes are replaced Defective hoses must be replaced Step Procedure Reference 1 Open the lower...

Page 34: ...he apparatus you make a substantial contribution to the safety of the system and to a long period of trouble free operation The condensate tank has to be checked every day and to be emptied if necessa...

Page 35: ...itch Audioswitch is for the I C BUS adaption for the connection of an external music signal with volume regulation and the connections to the MP3 players The memory card for the MP3 player can be chan...

Page 36: ...00 hours of operation the aquaCool nozzles have to be replaced in order to ensure that aquaCool stays fully operative and efficient The installation instructions will be enclosed in your spare parts c...

Page 37: ...roken or missing Mains voltage 3 phase 3x 220 V 60 Hz 2 phase 2x 220 V 60 Hz Wire cross section 3 phase 4x AWG6 2 phase 3x AWG8 Outlet At the left hand rear side of the unit Disposal Connection to sew...

Page 38: ...Facial units megaLine HP 500 Power 4x 500W Filter panes evo19525 3020019525 Tubes Canopy 27x megaLine 1856 R 200W HP Tubes Bench 21x megaLine 1855 R 160W HP Shoulder tanner 2x ms 250 Rated capacity W...

Page 39: ...L 6900 gnge 1 3 2 PE L3 L2 L1 Operation and Service KBL 6900 MAX10 7 Wiring diagram 7 1 Mains voltage The sunbed is by default set up to operate on 3 phases but it can be changed over to 2 phase opera...

Page 40: ...7 2 megaVoice without music option Music ampli er 3220 2885 00 Via an interface card the MP3 player megaVoice is connected to the music ampli er which leads to the loudspeakers connected in parallel...

Page 41: ...c signal without channel selection To connect the music signal use a 2 pole shielded cable the shield has to be earthed at the signal source The cable is connected to the marked clamps of the Audio sw...

Page 42: ...ld has to be earthed at the signal source The cable is connected to the marked clamps of the Audio switch The potentiometer is used to set the signal The loudspeakers are connected in parallel equal p...

Page 43: ...t cover and pull out the electronics carriage completely The console with the spacer supports for the board can be found inside at the right side of the electronics carriage Illustr 7 8 1 2 Attach the...

Page 44: ...ing signal from the coin token box system In case there is an error message you need to reset this message by touching the Stop sensor eld Illustr 8 1 Touch keys 1 0 for service operations Service lev...

Page 45: ...N Timer B OFF PIN II Enter the correct PIN Serviceebene II Gate ON OFF B Timer AR Cont 99 AAC Aroma Solar ON OFF Booth ON OFF B Inter 00 h Aqua ON OFF AQ Time Cycle Color R G B Extern Volume Nonstop E...

Page 46: ...eration Info In this menu the service hours of the sunbed WORK and the burning time of the tubes TUBE are displayed With the START key you open the sub menus With the STOP key you go back one level hi...

Page 47: ...g on and two times for switching off the decorative lighting for any day of the week If you do not need the switching time you can delete it by pressing key 1 The hours are set using keys 2 4 and the...

Page 48: ...This is a sub menu of AAC and it has also 6 sub menus SOLAR ON OFF A fragrance is or is not sprayed off on the sunbed BOOTH ON OFF A fragrance is or is not sprayed off in the booth PIN II opens servic...

Page 49: ...replaced the tin with the aroma gel this message has to be acknowledged see 8 3 and 8 4 by pressing touch key 1 These sub menus can be selected as in all the other menus by pressing the keys 0 and 5 T...

Page 50: ...as been selected When all keys have been pressed all the letters will ash i e the colour stimulation has been inactivated It is only possible to choose one colour by pressing the corresponding key Cyc...

Page 51: ...ning cycle CH The channel selection may be changed from channel and volume selection to BCD selection of a music source It is possible to select up to 4 music sources The volu me is adjusted at the mu...

Page 52: ...ator can preselect which source is selected after the start of the tanning program Press the key 4 or the key 9 The appropri ate character W P or S is shown in the PRESEL menu During the tanning progr...

Page 53: ...service level II 8 3 2 Menus of service level II Conguration menus In this menu functions can be activated or inactivated This makes sense when the corresponding function is missing or temporarily not...

Page 54: ...s are accepted by pressing the START key AR AQ Tube hours In this menu you can set the service hours of the tubes in steps of 5 hours This display has to be reset to zero after each tube replacement A...

Page 55: ...asyCare here 5 3 or with easycare here 1 8 Test You can also test the three functions Aroma aquaCool and aquaExtra without a tanning program After selecting a function press key 1 to start the test aq...

Page 56: ...ull the holding element of water tank and aroma tin forward 3 Move the covering handle on the lid of the aroma tin to the left 1 and then move the lid upward 2 Now you can replace the tin 4 Unscrew th...

Page 57: ...arked with colour points Blue compressed air for aquaCool Red re ux aquaCool Green ow pipe aquaCool Yellow aroma Colour code Abb 8 2 Compressor Abb 8 3 aquaCool Abb 8 4 aroma Abb 8 5 Canopy underside...

Page 58: ...ard and the revolution control Reason defective or not connected I C revolution control E02 BUS TMP Reason defective or not connected I C temperature sensor Solution press the START key The blower is...

Page 59: ...xposures 5 Special care is necessary in cases of pronounced individual sensitivity to UV radiation and in cases where certain medicines or cosmetics are applied 6 It cannot be said in any case that th...

Page 60: ...KBL AG Ringstra e 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66...

Reviews:

Related manuals for 6900 MAX10