26
Operation and Service megaSun 4500
4.
Technical data
4.1. Data that is common to all unit models
A notice board bearing the following wording must be perma-
nently
fi
xed at the cubicle wall near the tanning unit:
Warning:
UV radiation may cause damage to eyes and skin.
Ask the operating staff for further information. Wear protective
goggles. Certain medicaments or cosmetics may increase the
sensitivity. (UV type of the unit )
Ambiant conditions
Condensate
Electrical connection
Installation site
in dry rooms with suf
fi
cient air supply and ventilation
Relative air humidity
<70 %
Ambient temperature
<30°C (86°F)
ATTENTION!
The unit must not be operated in case the coin-box timer
system or the internal monitoring of the maximum tan-
ning time is faulty or if a
fi
lter broken or missing.
Water outlet
in dry rooms with suf
fi
cient air supply and ventilation
Disposal
connection to sewage system or tank (capacity
≥
5 litres)
Quantity
depends on the local conditions and the air humidity
Note!
As the condensate has to be pumped out, the power
supply must not be disconnected, not even after the
tanning session.
Mains voltage
400 V / 3N / 50 Hz
Fuses
3-pole slow-blow fuse protection; further details available
with the technical data of the respective model
Cable cross section
5 x 2.5 mm² Oil
fl
ex
Internal plug socket
for PCs, lamps, or similar items;
NOT to connect
welding
equipment, angle grinders or similar devices