SERVICING THE VENTILATION SYSTEM
⇒
Check all hose connections.
⇒
Remove any kinks in the air hoses. Replace
defective hoses immediately.
The exhaust air hose must not exceed a maximum length
of 6 m if there is no auxiliary fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump
㉘
pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
⇒
Fill some water into the condensate tray
㉙
.
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
⇒
Start a tanning session and then wait for 20
minutes.
⇒
The filling level of the tray must then be below
the pump level.
EMPTYING THE CONDENSATE TANK
The condensate pump transports the condensation
water into a canister via a hose. Once this condensate
canister is full, a corresponding message is displayed.
The air-conditioning symbol flashes (check), and the
air-conditioning unit switches off shortly afterwards.
50
㉚
㉛
㉚
Unscrew the closing lid of the condensate
canister.
㉛
Empty the condensate canister.
When closing, make sure that the condensate
hose is inserted a max. of 50 mm into the
canister.
⇒
Finally, acknowledge the aircon message on
the interior control panel (START).
Recording to an SD card
↵
REMOVING THE SD CARD
The SD card slot which contains the storage medium
with the MP3 data from the internal MP3 player is
located at the control box in the bench part of the tan
-
ning device.
N A U D O J I M O I N S T R U K C I J A
| megaSun 4800
48
Summary of Contents for MegaSun 4800
Page 1: ...NAUDOJIMO INSTRUKCIJA...
Page 2: ......
Page 57: ...N A U D O J I M O I N S T R U K C I J A megaSun 4800 57 Pastabos...
Page 58: ...N A U D O J I M O I N S T R U K C I J A megaSun 4800 58 Pastabos...
Page 59: ......