INFORMATION MESSAGES
No.
Info. message
Description
Remedy
203
Fill level aquaCool canister low
The content of the aquaCool canister is sufficient
for another 2.5 hours of operation with a spraying
time of 6 seconds each.
Replace the empty aquaCool canister with a full one. Do not
replace aquaCool with any other liquid.
204
Connection aquaCool unit faulty
Communication between control and module /
interior control panel has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact your
Customer Service.
205
Connection audio module faulty
206
Connection inside display faulty
207
aquaCool canister empty
aquaCool canister empty.
Replace the aquaCool canister with a full one.
See chapter: Refilling Aroma and aquacool
208
Aroma supply low, please renew
System has run out of scent.
Replace the Aroma tin.
See chapter: Refilling Aroma and aquacool
209
aircon:condensed-water canister
full, please empty
Condensate canister of air-conditioning unit full.
Empty the condensate canister of the air-conditioning unit,
acknowledge the message by pressing START.
210
Low battery charge, please renew
Button cell (CR-2032) of the control board
discharged.
Replace the button cell (CR-2032).
211
Connection preselect display
faulty
Communication
between
control
and
“preSelection” display has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact your
Customer Service.
212
Connection RGB-module faulty
213
SD card missing
No SD card in the audio module.
Insert an original SD card.
See chapter: Recording to an SD card/Removing the SD card
214
SD card unreadable
SD card defective, incompatible content.
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter: Recording to an SD
card/Removing the SD card. If the fault persists, contact your
Customer Service.
215
Connection to easy Care terminal
faulty
Communication between control and easyCare
terminal has been interrupted.
Check cable connections and power supply. Acknowledge the
message by pressing START. If the fault persists, contact your
Customer Service.
216
Voltage varies, blease check
Power supply to the mainboard varies
Check power supply to the mainboard.
217
No voice files on the SD card,
pleas check.
No voice files on the SD card found.
Rebuild voice folder on the SD card. If necessary replace original
SD card.
226
Quicktest Sensortoleranz
OK
Sensor Quicktest log entry - No display appears
- Message will be stored directly in the event log
(service menu).
-
227
Quicktest Sensortolerance
error
230
Connection Bluetooth module
faulty
Communication between control and bluetooth
module has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact your
Customer Service.
231
No display
Internal notification - stored in the error log (ser
-
vice technician information).
-