Replacing Aroma and aquaCool
media
↵
Attention!
Do not use any agents other than aquaCool
and Ar
oma gel supplied by KBL!
•
Risk of infections
•
Function of nozzles impaired
REPLACING THE AQUACOOL CANISTER
Due to the system a residual amount
remains in the canister.
If the aquaCool canister is empty, corresponding
messages are displayed, and aquaCool switches off
shortly afterwards.
㉜
㉝
Page
40
Open the bench part.
㉜
Unscrew the lid
Keep the hose end including the lid in a clean
plastic bag while replacing the canister.
㉝
Replace the canister.
⇒
Start aquaCool initialization (service menu).
REPLACING THE AROMA TIN
When the Aroma tin is empty, a corresponding
message is displayed.
㉟
㉞
Page
40
Open the bench part.
㉞
Unlock the retaining bracket.
㉟
Replace the tin.
⇒
Reset the Aroma counter in the service
menu to 0 (Reset). Then the message on the
display will disappear.
Replacing the aquaCool
nozzles
After 1,000 hours of operation, the aquaCool nozzles
must be replaced in order to ensure that the aquaCool
system functions properly. The assembly instructions
are included with your spare parts delivery.
O p e r a t i n g I n s t r u c t i o n s
|
megaSun 4800
50