Figure 47.1 Energy saving lamps in the canopy and its ballast
Filter pads
CLEANING CYCLE
The cooling air is sucked in via two dust fi lters.
Depending on the location, clean the fi lter pads
after approx. 100 hour of operation, or replace
them, if necessary. Only use original fi lter pads for
replacement in order to ensure a troublefree operation.
Take the opportunity to check if the heat exchangers
inside the air-conditioning unit are soiled. Dirty heat
exchangers substantially reduce the performance
of the air-conditioning unit. Vacuum-clean them if
necessary.
FILTER PAD IN THE CANOPY SECTION
You can easily replace the fi lter pad installed on the
rear side of the canopy.
Figure 47.2: Filter pad in the canopy
FILTER PAD IN THE BASE SECTION
The fi lter pad is located behind the decorative lighting
in the base section. Open the bed pane and remove
the fl uorescent tube to get access to the fi lter pad.
Figure 47.3: Filter pad in the base section
Canopy drive
REGULAR MAINTENANCE
In order to ensure a troublefree operation of the drive,
carry out the maintenance of the ropes after each
tube replacement (see table below, item 1).
TENSIONING THE SPRINGS
As soon as the canopy of the tanning system does
not remain safely in its upper position any more, the
two springs must be tensioned. To do so, a ratchet
spanner with hexagon socket (10 mm width across fl ats)
is required.
Procedure
Fig.
1
Check the spring ropes for wear.
Should individual rope wires have
spliced, always replace both ropes.
2
Remove the side pane.
3
There are tensioning screws on the
right-hand and left-hand side.
47.4
47.5
4
Tension both springs equally.
5
Check the canopy drive: the canopy
stops in all positions.
6
Close the side pane again.
Figure 47.4: Figure 47.5:
Tensioning spring on
Tensioning spring on
the left-hand side the right-hand side
O p e r a t i n g I n s t r u c t i o n s
|
megaSun 5600
47